What was found in ZIP 80134
The highest level seen across the suppliers serving this ZIP, the EPA limit for each, and where the figure comes from.
| Contaminant | Level vs EPA limit | Suppliers | Source |
|---|---|---|---|
| Nitrate-Nitrite | 2500 µg/L 25% of the EPA limit 10000 µg/L | 3/5 | SYR4 |
| Nitrate | 2400 µg/L 24% of the EPA limit 10000 µg/L | 4/5 | SYR4 |
| Fluoride | 1900 µg/L 48% of the EPA limit 4000 µg/L | 5/5 | SYR4 |
| Chlorite | 350 µg/L 35% of the EPA limit 1000 µg/L | 1/5 | SYR4 |
| Barium | 260 µg/L 13% of the EPA limit 2000 µg/L | 5/5 | SYR4 |
| Nitrite | 120 µg/L 12% of the EPA limit 1000 µg/L | 2/5 | SYR4 |
| TTHM | 57.2 µg/L 72% of the EPA limit 80 µg/L | 5/5 | SYR4 |
| Lithium | 42 µg/L No EPA limit set | 5/5 | UCMR-5 |
| Total Haloacetic Acids (HAA5) | 38 µg/L 63% of the EPA limit 60 µg/L | 5/5 | SYR4 |
| Combined Uranium | 31 µg/L 103% of the EPA limit, in the worst sample — 30 µg/L | 4/5 | SYR4 |
| Chloroform | 30.2 µg/L No EPA limit set | 5/5 | SYR4 |
| Gross Alpha, Excl. Radon And U | 27.23 pCi/L 182% of the EPA limit, in the worst sample — 15 pCi/L | 5/5 | SYR4 |
| Cyanide | 25 µg/L 13% of the EPA limit 200 µg/L | 1/5 | SYR4 |
| Dibromochloromethane | 24 µg/L No EPA limit set | 5/5 | SYR4 |
| Bromodichloromethane | 18.5 µg/L No EPA limit set | 5/5 | SYR4 |
| Dichloroacetic Acid | 17.7 µg/L No EPA limit set | 5/5 | SYR4 |
| Gross Beta Particle Activity | 13.1 pCi/L No EPA limit set | 3/5 | SYR4 |
| Di(2-ethylhexyl) Adipate | 11 µg/L 2.8% of the EPA limit 400 µg/L | 1/5 | SYR4 |
| Monochloroacetic Acid | 10.7 µg/L No EPA limit set | 2/5 | SYR4 |
| Bromoform | 10 µg/L No EPA limit set | 5/5 | SYR4 |
| Trichloroacetic Acid | 9.9 µg/L No EPA limit set | 5/5 | SYR4 |
| Dibromoacetic Acid | 8.9 µg/L No EPA limit set | 4/5 | SYR4 |
| Selenium | 6.8 µg/L 14% of the EPA limit 50 µg/L | 3/5 | SYR4 |
| Combined Radium (-226 And -228) | 6.5 pCi/L 130% of the EPA limit, in the worst sample — 5 pCi/L | 5/5 | SYR4 |
| Di(2-ethylhexyl) Phthalate | 4.6 µg/L 77% of the EPA limit 6 µg/L | 2/5 | SYR4 |
| Toluene | 4.6 µg/L 0.5% of the EPA limit 1000 µg/L | 1/5 | SYR4 |
| Arsenic | 4.1 µg/L 41% of the EPA limit 10 µg/L | 3/5 | SYR4 |
| Chromium | 4 µg/L 4% of the EPA limit 100 µg/L | 3/5 | SYR4 |
| Monobromoacetic Acid | 3.2 µg/L No EPA limit set | 4/5 | SYR4 |
| Antimony, Total | 2.3 µg/L 38% of the EPA limit 6 µg/L | 3/5 | SYR4 |
| Carbon Tetrachloride | 0.5000 µg/L 10% of the EPA limit 5 µg/L | 1/5 | SYR4 |
| Diquat | 0.3800 µg/L 1.9% of the EPA limit 20 µg/L | 1/5 | SYR4 |
| 2,4-D | 0.1000 µg/L 0.1% of the EPA limit 70 µg/L | 1/5 | SYR4 |
| Cadmium | 0.1000 µg/L 2% of the EPA limit 5 µg/L | 1/5 | SYR4 |
| Mercury | 0.0700 µg/L 3.5% of the EPA limit 2 µg/L | 1/5 | SYR4 |
| Hexachlorocyclopentadiene | 0.0650 µg/L 0.1% of the EPA limit 50 µg/L | 1/5 | SYR4 |
| Beryllium, Total | 0.0600 µg/L 1.5% of the EPA limit 4 µg/L | 1/5 | SYR4 |
| Thallium, Total | 0.0600 µg/L 3% of the EPA limit 2 µg/L | 1/5 | SYR4 |
| Pfpea | 0.0140 µg/L No EPA limit set | 3/5 | UCMR-5 |
| Pfhxa | 0.0119 µg/L No EPA limit set | 3/5 | UCMR-5 |
| Hexachlorobenzene | 0.0097 µg/L 1% of the EPA limit 1 µg/L | 2/5 | SYR4 |
| Pfba | 0.0086 µg/L No EPA limit set | 3/5 | UCMR-5 |
| PFBS | 0.0053 µg/L No EPA limit set | 3/5 | UCMR-5 |
| PFOA | 0.0048 µg/L No EPA limit set | 2/5 | UCMR-5 |
| Lead | 0.0031 mg/L 21% of the EPA limit 0.0150 mg/L | 5/5 | LCR |
Water suppliers serving ZIP 80134
| Supplier | State | Population served |
|---|---|---|
| DENVER WATER BOARD | CO | 1,287,000 |
| PARKER WSD | CO | 75,949 |
| MERIDIAN MD | CO | 23,415 |
| PINERY WWD | CO | 12,901 |
| COTTONWOOD WSD | CO | 10,867 |
Frequently asked questions about ZIP 80134 tap water
Is the tap water in ZIP 80134 safe to drink?
EPA testing detected 45 contaminants across the water suppliers serving ZIP 80134. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.
Which water suppliers serve ZIP 80134?
5 public water suppliers report EPA drinking-water monitoring for ZIP 80134. Each is listed above with its population served.
What contaminants are in ZIP 80134's water?
EPA monitoring detected Nitrate-Nitrite, Nitrate, Fluoride, Chlorite, Barium, and others across this ZIP's suppliers. The full list with levels and sources is above.