← Colorado

Tap water quality report

Denver, CO

EPA monitoring detected 32 contaminants across the 4 water suppliers serving Denver. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

4
water suppliers
1,312,697
people served
32
contaminants found

What was found in Denver's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
1080 µg/L 27%
of the EPA limit 4000 µg/L
1/4 SYR4
Nitrate
660 µg/L 6.6%
of the EPA limit 10000 µg/L
1/4 SYR4
Nitrate-Nitrite
290 µg/L 2.9%
of the EPA limit 10000 µg/L
1/4 SYR4
Barium
50 µg/L 2.5%
of the EPA limit 2000 µg/L
1/4 SYR4
TTHM
41.64 µg/L 52%
of the EPA limit 80 µg/L
1/4 SYR4
Total Haloacetic Acids (HAA5)
38 µg/L 63%
of the EPA limit 60 µg/L
1/4 SYR4
Chloroform
30.2 µg/L
No EPA limit set
1/4 SYR4
Cyanide
25 µg/L 13%
of the EPA limit 200 µg/L
1/4 SYR4
Dichloroacetic Acid
17.7 µg/L
No EPA limit set
1/4 SYR4
Bromodichloromethane
11.6 µg/L
No EPA limit set
1/4 SYR4
Lithium
10.8 µg/L
No EPA limit set
1/4 UCMR-5
Trichloroacetic Acid
9.9 µg/L
No EPA limit set
1/4 SYR4
Selenium
6.8 µg/L 14%
of the EPA limit 50 µg/L
1/4 SYR4
Combined Uranium
6.3 µg/L 21%
of the EPA limit 30 µg/L
1/4 SYR4
Dibromochloromethane
6 µg/L
No EPA limit set
1/4 SYR4
Monochloroacetic Acid
4.9 µg/L
No EPA limit set
1/4 SYR4
Chromium
4 µg/L 4%
of the EPA limit 100 µg/L
1/4 SYR4
Monobromoacetic Acid
3.2 µg/L
No EPA limit set
1/4 SYR4
Gross Beta Particle Activity
3 pCi/L
No EPA limit set
1/4 SYR4
Combined Radium (-226 And -228)
2 pCi/L 40%
of the EPA limit 5 pCi/L
1/4 SYR4
Gross Alpha, Excl. Radon And U
2 pCi/L 13%
of the EPA limit 15 pCi/L
1/4 SYR4
Dibromoacetic Acid
1.7 µg/L
No EPA limit set
1/4 SYR4
Arsenic
1.2 µg/L 12%
of the EPA limit 10 µg/L
1/4 SYR4
Bromoform
1 µg/L
No EPA limit set
1/4 SYR4
Carbon Tetrachloride
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/4 SYR4
Antimony, Total
0.2800 µg/L 4.7%
of the EPA limit 6 µg/L
1/4 SYR4
2,4-D
0.1000 µg/L 0.1%
of the EPA limit 70 µg/L
1/4 SYR4
Cadmium
0.1000 µg/L 2%
of the EPA limit 5 µg/L
1/4 SYR4
Mercury
0.0700 µg/L 3.5%
of the EPA limit 2 µg/L
1/4 SYR4
Beryllium, Total
0.0600 µg/L 1.5%
of the EPA limit 4 µg/L
1/4 SYR4
Thallium, Total
0.0600 µg/L 3%
of the EPA limit 2 µg/L
1/4 SYR4
Lead
0.0090 mg/L 60%
of the EPA limit 0.0150 mg/L
4/4 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Denver

SupplierPopulation served
DENVER WATER BOARD 1,287,000
CHERRY CREEK VALLEY WSD 22,000
ADVENIR FRENCH QUARTER 3,447
GARDEN MEADOWS 250

Frequently asked questions about Denver tap water

Is Denver tap water safe to drink?

EPA testing detected 32 contaminants in the water serving Denver. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Denver?

4 public water suppliers report drinking-water monitoring for Denver, Colorado to the EPA. Each is listed above with its population served.

What contaminants are in Denver's water?

The contaminants EPA monitoring detected in Denver include Fluoride, Nitrate, Nitrate-Nitrite, Barium, TTHM. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.