← Texas

Tap water quality report

Brownwood, TX

EPA monitoring detected 24 contaminants across the 4 water suppliers serving Brownwood. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

4
water suppliers
35,184
people served
24
contaminants found

What was found in Brownwood's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
173 µg/L 13%
of the EPA limit 1300 µg/L
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2017
Highest in the city: 619.1 µg/L — BROOKESMITH SPECIAL UTILITY DISTRICT · 13,026 people · 2018
4/4 SYR4
Nitrate
263.5 µg/L 2.6%
of the EPA limit 10000 µg/L
Highest in the city: BROWN COUNTY WID 1 · 0 people · 2019
1/4 SYR4
Fluoride
246.5 µg/L 6.2%
of the EPA limit 4000 µg/L
Highest in the city: BROWN COUNTY WID 1 · 0 people · 2019
1/4 SYR4
Nitrate-Nitrite
201 µg/L 2%
of the EPA limit 10000 µg/L
Highest in the city: BROWN COUNTY WID 1 · 0 people · 2015
1/4 SYR4
Cyanide
180.5 µg/L 90%
of the EPA limit 200 µg/L
Highest in the city: BROWN COUNTY WID 1 · 0 people · 2019
1/4 SYR4
Barium
139.3 µg/L 7%
of the EPA limit 2000 µg/L
Highest in the city: BROWN COUNTY WID 1 · 0 people · 2019
1/4 SYR4
TTHM
85.3 µg/L 107%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2019
Highest in the city: 90.49 µg/L — BROOKESMITH SPECIAL UTILITY DISTRICT · 13,026 people · 2019
4/4 SYR4
Total Haloacetic Acids (HAA5)
47.09 µg/L 78%
of the EPA limit 60 µg/L
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2019
Highest in the city: 60.73 µg/L — BROWN COUNTY WID 1 · 0 people · 2019
4/4 SYR4
Chloroform
46.72 µg/L
No EPA limit set
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2019
4/4 SYR4
Dichloroacetic Acid
28.58 µg/L
No EPA limit set
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2019
Highest in the city: 36.525 µg/L — BROWN COUNTY WID 1 · 0 people · 2019
4/4 SYR4
Dibromochloromethane
24.47 µg/L
No EPA limit set
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2019
Highest in the city: 29.19 µg/L — BROOKESMITH SPECIAL UTILITY DISTRICT · 13,026 people · 2019
4/4 SYR4
Bromodichloromethane
25.74 µg/L
No EPA limit set
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2019
Highest in the city: 25.9 µg/L — BROWN COUNTY WID 1 · 0 people · 2019
4/4 SYR4
Lead
3.541 µg/L 24%
of the EPA limit 15 µg/L
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2017
Highest in the city: 21.8 µg/L — BROOKESMITH SPECIAL UTILITY DISTRICT · 13,026 people · 2018
3/4 SYR4
Trichloroacetic Acid
16.25 µg/L
No EPA limit set
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2019
Highest in the city: 21.4 µg/L — BROWN COUNTY WID 1 · 0 people · 2019
4/4 SYR4
Bromoform
12.39 µg/L
No EPA limit set
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2019
Highest in the city: 16.255 µg/L — BROOKESMITH SPECIAL UTILITY DISTRICT · 13,026 people · 2019
4/4 SYR4
Dibromoacetic Acid
9.9 µg/L
No EPA limit set
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2019
Highest in the city: 12.555 µg/L — BROOKESMITH SPECIAL UTILITY DISTRICT · 13,026 people · 2019
4/4 SYR4
Monochloroacetic Acid
6.765 µg/L
No EPA limit set
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2019
Highest in the city: 8.08 µg/L — CITY OF EARLY · 3,296 people · 2019
4/4 SYR4
Gross Beta Particle Activity
6.1 pCi/L
No EPA limit set
Highest in the city: BROWN COUNTY WID 1 · 0 people · 2017
1/4 SYR4
Selenium
4.25 µg/L 8.5%
of the EPA limit 50 µg/L
Highest in the city: BROWN COUNTY WID 1 · 0 people · 2019
1/4 SYR4
Monobromoacetic Acid
2.415 µg/L
No EPA limit set
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2019
Highest in the city: 4 µg/L — BROWN COUNTY WID 1 · 0 people · 2019
3/4 SYR4
Arsenic
3.045 µg/L 30%
of the EPA limit 10 µg/L
Highest in the city: BROWN COUNTY WID 1 · 0 people · 2019
1/4 SYR4
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
Highest in the city: BROWN COUNTY WID 1 · 0 people · 2017
1/4 SYR4
Pfba
0.0108 µg/L
No EPA limit set
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2024
2/4 UCMR-5
Lead
0.0051 mg/L 34%
of the EPA limit 0.0150 mg/L
Main supplier: CITY OF BROWNWOOD · 18,862 people · 2023
3/4 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Brownwood

Frequently asked questions about Brownwood tap water

Is Brownwood tap water safe to drink?

EPA testing detected 24 contaminants in the water serving Brownwood. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Brownwood?

4 public water suppliers report drinking-water monitoring for Brownwood, Texas to the EPA. Each is listed above with its population served.

What contaminants are in Brownwood's water?

The contaminants EPA monitoring detected in Brownwood include Copper, Nitrate, Fluoride, Nitrate-Nitrite, Cyanide. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.