Tap water quality report

Vidor, TX

EPA monitoring detected 33 contaminants across the 9 water suppliers serving Vidor. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

9
water suppliers
16,653
people served
33
contaminants found

What was found in Vidor's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
930 µg/L 23%
of the EPA limit 4000 µg/L
8/9 SYR4
Copper
487 µg/L 37%
of the EPA limit 1300 µg/L
9/9 SYR4
Barium
260 µg/L 13%
of the EPA limit 2000 µg/L
9/9 SYR4
TTHM
255 µg/L 319%
of the EPA limit, in the worst sample — 80 µg/L
9/9 SYR4
Chloroform
221 µg/L
No EPA limit set
9/9 SYR4
Lead
146 µg/L 973%
of the EPA limit, in the worst sample — 15 µg/L
9/9 SYR4
Total Haloacetic Acids (HAA5)
135 µg/L 225%
of the EPA limit, in the worst sample — 60 µg/L
9/9 SYR4
Nitrate
120 µg/L 1.2%
of the EPA limit 10000 µg/L
8/9 SYR4
Trichloroacetic Acid
117.5 µg/L
No EPA limit set
9/9 SYR4
Dichloroacetic Acid
111 µg/L
No EPA limit set
9/9 SYR4
Dibromochloromethane
70.5 µg/L
No EPA limit set
9/9 SYR4
Cyanide
70 µg/L 35%
of the EPA limit 200 µg/L
1/9 SYR4
Bromodichloromethane
55.2 µg/L
No EPA limit set
9/9 SYR4
Bromoform
39.5 µg/L
No EPA limit set
6/9 SYR4
Nitrite
20 µg/L 2%
of the EPA limit 1000 µg/L
1/9 SYR4
Lithium
19.2 µg/L
No EPA limit set
1/9 UCMR-5
Dibromoacetic Acid
14.6 µg/L
No EPA limit set
8/9 SYR4
Monochloroacetic Acid
14.5 µg/L
No EPA limit set
4/9 SYR4
Arsenic
13 µg/L 130%
of the EPA limit, in the worst sample — 10 µg/L
5/9 SYR4
Nitrate-Nitrite
10 µg/L 0.1%
of the EPA limit 10000 µg/L
2/9 SYR4
Gross Beta Particle Activity
4.4 pCi/L
No EPA limit set
1/9 SYR4
Selenium
3.6 µg/L 7.2%
of the EPA limit 50 µg/L
1/9 SYR4
Dalapon
3.4 µg/L 1.7%
of the EPA limit 200 µg/L
1/9 SYR4
Xylenes, Total
3.1 µg/L 0%
of the EPA limit 10000 µg/L
1/9 SYR4
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
3/9 SYR4
Monobromoacetic Acid
1.2 µg/L
No EPA limit set
1/9 SYR4
Di(2-ethylhexyl) Phthalate
0.8400 µg/L 14%
of the EPA limit 6 µg/L
2/9 SYR4
Hexachlorocyclopentadiene
0.3400 µg/L 0.7%
of the EPA limit 50 µg/L
1/9 SYR4
Atrazine
0.1100 µg/L 3.7%
of the EPA limit 3 µg/L
1/9 SYR4
Picloram
0.1000 µg/L 0%
of the EPA limit 500 µg/L
1/9 SYR4
Ethylene Dibromide
0.0100 µg/L 20%
of the EPA limit 0.0500 µg/L
1/9 SYR4
Pfba
0.0053 µg/L
No EPA limit set
1/9 UCMR-5
Lead
0.0042 mg/L 28%
of the EPA limit 0.0150 mg/L
9/9 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Vidor

Frequently asked questions about Vidor tap water

Is Vidor tap water safe to drink?

EPA testing detected 33 contaminants in the water serving Vidor. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Vidor?

9 public water suppliers report drinking-water monitoring for Vidor, Texas to the EPA. Each is listed above with its population served.

What contaminants are in Vidor's water?

The contaminants EPA monitoring detected in Vidor include Fluoride, Copper, Barium, TTHM, Chloroform. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.