EPA monitoring detected 63 contaminants across the 4 water suppliers serving Prospect. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

4
water suppliers
549,371
people served
63
contaminants found

What was found in Prospect's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate-Nitrite
10300 µg/L 103%
of the EPA limit, in the worst sample — 10000 µg/L
4/4 SYR4
Nitrate
3715 µg/L 37%
of the EPA limit 10000 µg/L
4/4 SYR4
Fluoride
2320 µg/L 58%
of the EPA limit 4000 µg/L
4/4 SYR4
Copper
1550 µg/L 119%
of the EPA limit, in the worst sample — 1300 µg/L
4/4 SYR4
Lead
656 µg/L 4373%
of the EPA limit, in the worst sample — 15 µg/L
4/4 SYR4
Nitrite
448 µg/L 45%
of the EPA limit 1000 µg/L
3/4 SYR4
Barium
301 µg/L 15%
of the EPA limit 2000 µg/L
4/4 SYR4
TTHM
122.7 µg/L 153%
of the EPA limit, in the worst sample — 80 µg/L
4/4 SYR4
Chloroform
96 µg/L
No EPA limit set
4/4 SYR4
Total Haloacetic Acids (HAA5)
72.9 µg/L 122%
of the EPA limit, in the worst sample — 60 µg/L
4/4 SYR4
Cyanide
50 µg/L 25%
of the EPA limit 200 µg/L
1/4 SYR4
Trichloroacetic Acid
45.3 µg/L
No EPA limit set
3/4 SYR4
Dichloroacetic Acid
28.7 µg/L
No EPA limit set
3/4 SYR4
Bromodichloromethane
24.6 µg/L
No EPA limit set
4/4 SYR4
1,2,4-Trichlorobenzene
24.4 µg/L 35%
of the EPA limit 70 µg/L
1/4 SYR4
Monochloroacetic Acid
10.4 µg/L
No EPA limit set
3/4 SYR4
Gross Beta Particle Activity
8.5 pCi/L
No EPA limit set
1/4 SYR4
Monobromoacetic Acid
6 µg/L
No EPA limit set
2/4 SYR4
Dibromochloromethane
5.5 µg/L
No EPA limit set
4/4 SYR4
Gross Alpha, Excl. Radon And U
5.18 pCi/L 35%
of the EPA limit 15 pCi/L
2/4 SYR4
Bromoform
3.1 µg/L
No EPA limit set
4/4 SYR4
Combined Radium (-226 And -228)
2.27 pCi/L 45%
of the EPA limit 5 pCi/L
3/4 SYR4
Toxaphene
2.2 µg/L 73%
of the EPA limit 3 µg/L
1/4 SYR4
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
2/4 SYR4
Dibromoacetic Acid
1.7 µg/L
No EPA limit set
3/4 SYR4
Combined Uranium
1.49 µg/L 5%
of the EPA limit 30 µg/L
1/4 SYR4
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
1/4 SYR4
Selenium
1 µg/L 2%
of the EPA limit 50 µg/L
1/4 SYR4
Thallium, Total
1 µg/L 50%
of the EPA limit 2 µg/L
1/4 SYR4
Antimony, Total
0.8000 µg/L 13%
of the EPA limit 6 µg/L
1/4 SYR4
1,1,1-Trichloroethane
0.5000 µg/L 0.3%
of the EPA limit 200 µg/L
1/4 SYR4
1,1,2-Trichloroethane
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/4 SYR4
1,1-Dichloroethylene
0.5000 µg/L 7.1%
of the EPA limit 7 µg/L
1/4 SYR4
1,2-Dichloroethane
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/4 SYR4
1,2-Dichloropropane
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/4 SYR4
Benzene
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/4 SYR4
Chlorobenzene
0.5000 µg/L 0.5%
of the EPA limit 100 µg/L
1/4 SYR4
Carbon Tetrachloride
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/4 SYR4
Dichloromethane
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/4 SYR4
Ethylbenzene
0.5000 µg/L 0.1%
of the EPA limit 700 µg/L
1/4 SYR4
Styrene
0.5000 µg/L 0.5%
of the EPA limit 100 µg/L
1/4 SYR4
Tetrachloroethylene
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/4 SYR4
Toluene
0.5000 µg/L 0.1%
of the EPA limit 1000 µg/L
1/4 SYR4
Trichloroethylene
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/4 SYR4
Vinyl Chloride
0.5000 µg/L 25%
of the EPA limit 2 µg/L
1/4 SYR4
cis-1,2-Dichloroethylene
0.5000 µg/L 0.7%
of the EPA limit 70 µg/L
1/4 SYR4
O-Dichlorobenzene
0.5000 µg/L 0.1%
of the EPA limit 600 µg/L
1/4 SYR4
P-Dichlorobenzene
0.5000 µg/L 0.7%
of the EPA limit 75 µg/L
1/4 SYR4
trans-1,2-Dichloroethylene
0.5000 µg/L 0.5%
of the EPA limit 100 µg/L
1/4 SYR4
2,4,5-TP
0.4400 µg/L 0.9%
of the EPA limit 50 µg/L
1/4 SYR4
Beryllium, Total
0.3000 µg/L 7.5%
of the EPA limit 4 µg/L
1/4 SYR4
Cadmium
0.3000 µg/L 6%
of the EPA limit 5 µg/L
1/4 SYR4
2,4-D
0.2200 µg/L 0.3%
of the EPA limit 70 µg/L
1/4 SYR4
Methoxychlor
0.2200 µg/L 0.5%
of the EPA limit 40 µg/L
1/4 SYR4
Mercury
0.2000 µg/L 10%
of the EPA limit 2 µg/L
1/4 SYR4
Asbestos
0.1700 MFL 2.4%
of the EPA limit 7 MFL
1/4 SYR4
Bhc-Gamma
0.0440 µg/L 22%
of the EPA limit 0.2000 µg/L
1/4 SYR4
Endrin
0.0220 µg/L 1.1%
of the EPA limit 2 µg/L
1/4 SYR4
PFOS
0.0107 µg/L
No EPA limit set
1/4 UCMR-5
PFOA
0.0071 µg/L
No EPA limit set
1/4 UCMR-5
Lead
0.0040 mg/L 27%
of the EPA limit 0.0150 mg/L
4/4 LCR
PFBS
0.0035 µg/L
No EPA limit set
1/4 UCMR-5
Pfpea
0.0031 µg/L
No EPA limit set
1/4 UCMR-5
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Prospect

Frequently asked questions about Prospect tap water

Is Prospect tap water safe to drink?

EPA testing detected 63 contaminants in the water serving Prospect. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Prospect?

4 public water suppliers report drinking-water monitoring for Prospect, Connecticut to the EPA. Each is listed above with its population served.

What contaminants are in Prospect's water?

The contaminants EPA monitoring detected in Prospect include Nitrate-Nitrite, Nitrate, Fluoride, Copper, Lead. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.