← California

Tap water quality report

ZIP 79906 — California

EPA monitoring across the 2 water suppliers serving ZIP 79906 in California detected 30 contaminants. A detection doesn't automatically mean the water is unsafe — see the highest level found below, with the EPA limit for each.

2
water suppliers
43,000
people served
30
contaminants found

What was found in ZIP 79906

The highest level seen across the suppliers serving this ZIP, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
5840 µg/L 58%
of the EPA limit 10000 µg/L
1/2 SYR4
Nitrate-Nitrite
5840 µg/L 58%
of the EPA limit 10000 µg/L
1/2 SYR4
Fluoride
1040 µg/L 26%
of the EPA limit 4000 µg/L
1/2 SYR4
Copper
830 µg/L 64%
of the EPA limit 1300 µg/L
2/2 SYR4
TTHM
133.6 µg/L 167%
of the EPA limit, in the worst sample — 80 µg/L
2/2 SYR4
Barium
110 µg/L 5.5%
of the EPA limit 2000 µg/L
1/2 SYR4
Lithium
62.6 µg/L
No EPA limit set
2/2 UCMR-5
Bromodichloromethane
49.1 µg/L
No EPA limit set
2/2 SYR4
Chloroform
46.3 µg/L
No EPA limit set
2/2 SYR4
Lead
45 µg/L 300%
of the EPA limit, in the worst sample — 15 µg/L
2/2 SYR4
Dibromochloromethane
44.9 µg/L
No EPA limit set
2/2 SYR4
Total Haloacetic Acids (HAA5)
25.6 µg/L 43%
of the EPA limit 60 µg/L
2/2 SYR4
Cyanide
22.9 µg/L 11%
of the EPA limit 200 µg/L
1/2 SYR4
Bromoform
22.3 µg/L
No EPA limit set
2/2 SYR4
Monochloroacetic Acid
14.3 µg/L
No EPA limit set
2/2 SYR4
Dichloroacetic Acid
12.8 µg/L
No EPA limit set
2/2 SYR4
Chromium
9.5 µg/L 9.5%
of the EPA limit 100 µg/L
1/2 SYR4
Dibromoacetic Acid
9.3 µg/L
No EPA limit set
2/2 SYR4
Gross Beta Particle Activity
8.8 pCi/L
No EPA limit set
1/2 SYR4
Trichloroacetic Acid
8.3 µg/L
No EPA limit set
2/2 SYR4
Gross Alpha, Excl. Radon And U
8 pCi/L 53%
of the EPA limit 15 pCi/L
1/2 SYR4
Selenium
7 µg/L 14%
of the EPA limit 50 µg/L
1/2 SYR4
Combined Uranium
6.9 µg/L 23%
of the EPA limit 30 µg/L
1/2 SYR4
Arsenic
5.3 µg/L 53%
of the EPA limit 10 µg/L
1/2 SYR4
Monobromoacetic Acid
2.6 µg/L
No EPA limit set
2/2 SYR4
Combined Radium (-226 And -228)
1.08 pCi/L 22%
of the EPA limit 5 pCi/L
1/2 SYR4
Lead
0.0046 mg/L 31%
of the EPA limit 0.0150 mg/L
2/2 LCR
Pfpea
0.0041 µg/L
No EPA limit set
1/2 UCMR-5
Pfhxa
0.0038 µg/L
No EPA limit set
2/2 UCMR-5
PFHXS
0.0037 µg/L
No EPA limit set
1/2 UCMR-5
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 79906

SupplierStatePopulation served
FORT BLISS MAIN POST AREA CA 28,000
EAST BIGGS WATER SYSTEM CA 15,000

Frequently asked questions about ZIP 79906 tap water

Is the tap water in ZIP 79906 safe to drink?

EPA testing detected 30 contaminants across the water suppliers serving ZIP 79906. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 79906?

2 public water suppliers report EPA drinking-water monitoring for ZIP 79906. Each is listed above with its population served.

What contaminants are in ZIP 79906's water?

EPA monitoring detected Nitrate, Nitrate-Nitrite, Fluoride, Copper, TTHM, and others across this ZIP's suppliers. The full list with levels and sources is above.