EPA monitoring across the 3 water suppliers serving ZIP 15904 in Johnstown, PA detected 18 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

3
water suppliers
79,917
people served
18
contaminants found

What was found in ZIP 15904

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
2800 µg/L 28%
of the EPA limit 10000 µg/L
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
Highest in the ZIP: 3000 µg/L — HIGHLAND S & W AUTH BEAVERDAM · 22,617 people · 2019
3/3 SYR4
Copper
149.35 µg/L 11%
of the EPA limit 1300 µg/L
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
Highest in the ZIP: 783.15 µg/L — CONEMAUGH TWP MUNI AUTH · 7,800 people · 2019
3/3 SYR4
Fluoride
709.6 µg/L 18%
of the EPA limit 4000 µg/L
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
1/3 SYR4
Monochloroacetic Acid
48.4 µg/L
No EPA limit set
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
Highest in the ZIP: 65.45 µg/L — HIGHLAND S & W AUTH BEAVERDAM · 22,617 people · 2019
3/3 SYR4
Total Haloacetic Acids (HAA5)
64.35 µg/L 107%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
3/3 SYR4
TTHM
57.745 µg/L 72%
of the EPA limit 80 µg/L
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
Highest in the ZIP: 61.95 µg/L — CONEMAUGH TWP MUNI AUTH · 7,800 people · 2019
3/3 SYR4
Chloroform
53.61 µg/L
No EPA limit set
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
Highest in the ZIP: 57.84 µg/L — CONEMAUGH TWP MUNI AUTH · 7,800 people · 2019
3/3 SYR4
Barium
41.65 µg/L 2.1%
of the EPA limit 2000 µg/L
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
3/3 SYR4
Dichloroacetic Acid
39.55 µg/L
No EPA limit set
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
3/3 SYR4
Trichloroacetic Acid
37.1 µg/L
No EPA limit set
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
3/3 SYR4
Dibromochloromethane
1.95 µg/L
No EPA limit set
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
Highest in the ZIP: 17.8385 µg/L — CONEMAUGH TWP MUNI AUTH · 7,800 people · 2019
3/3 SYR4
Lead
6.84 µg/L 46%
of the EPA limit 15 µg/L
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
Highest in the ZIP: 16.89 µg/L — CONEMAUGH TWP MUNI AUTH · 7,800 people · 2019
3/3 SYR4
Bromodichloromethane
7.5135 µg/L
No EPA limit set
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
Highest in the ZIP: 7.8265 µg/L — HIGHLAND S & W AUTH BEAVERDAM · 22,617 people · 2019
3/3 SYR4
Monobromoacetic Acid
2.007 µg/L
No EPA limit set
Highest in the ZIP: HIGHLAND S & W AUTH BEAVERDAM · 22,617 people · 2019
1/3 SYR4
Mercury
0.2700 µg/L 14%
of the EPA limit 2 µg/L
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
Highest in the ZIP: 0.7768 µg/L — HIGHLAND S & W AUTH BEAVERDAM · 22,617 people · 2019
3/3 SYR4
Dibromoacetic Acid
0.4400 µg/L
No EPA limit set
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2019
2/3 SYR4
Pfba
0.0132 µg/L
No EPA limit set
Highest in the ZIP: CONEMAUGH TWP MUNI AUTH · 7,800 people · 2023
1/3 UCMR-5
Lead
0.0050 mg/L 33%
of the EPA limit 0.0150 mg/L
Main supplier: GREATER JOHNSTOWN WA RIVERSIDE · 49,500 people · 2025
3/3 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 15904

SupplierStatePopulation served
GREATER JOHNSTOWN WA RIVERSIDE PA 49,500
HIGHLAND S & W AUTH BEAVERDAM PA 22,617
CONEMAUGH TWP MUNI AUTH PA 7,800

Frequently asked questions about ZIP 15904 tap water

Is the tap water in ZIP 15904 safe to drink?

EPA testing detected 18 contaminants across the water suppliers serving ZIP 15904. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 15904?

3 public water suppliers report EPA drinking-water monitoring for ZIP 15904. Each is listed above with its population served.

What contaminants are in ZIP 15904's water?

EPA monitoring detected Nitrate, Copper, Fluoride, Monochloroacetic Acid, Total Haloacetic Acids (HAA5), and others across this ZIP's suppliers. The full list with levels and sources is above.