← Oyster Bay, NY

Tap water quality report

ZIP 11801 — Oyster Bay, NY

EPA monitoring across the 1 water supplier serving ZIP 11801 in Oyster Bay, NY detected 37 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

1
water supplier
48,000
people served
37
contaminants found

What was found in ZIP 11801

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate-Nitrite
8730 µg/L 87%
of the EPA limit 10000 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Nitrate
8440 µg/L 84%
of the EPA limit 10000 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Copper
260 µg/L 20%
of the EPA limit 1300 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Fluoride
159.5 µg/L 4%
of the EPA limit 4000 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
cis-1,2-Dichloroethylene
21 µg/L 30%
of the EPA limit 70 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
1,1-Dichloroethylene
20.8 µg/L 297%
of the EPA limit, at the 95th percentile of samples — 7 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Barium
19.42 µg/L 1%
of the EPA limit 2000 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Tetrachloroethylene
19.4 µg/L 388%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Trichloroethylene
17.66 µg/L 353%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
1,1,2-Trichloroethane
10.34 µg/L 207%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
1,1,1-Trichloroethane
9.725 µg/L 4.9%
of the EPA limit 200 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Carbon Tetrachloride
7 µg/L 140%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Arsenic
6.8245 µg/L 68%
of the EPA limit 10 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Selenium
6.275 µg/L 13%
of the EPA limit 50 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Lead
5.9315 µg/L 40%
of the EPA limit 15 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
TTHM
3.505 µg/L 4.4%
of the EPA limit 80 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Nitrite
3.5 µg/L 0.4%
of the EPA limit 1000 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Combined Radium (-226 And -228)
3.36 pCi/L 67%
of the EPA limit 5 pCi/L
Main supplier: HICKSVILLE WD · 48,000 people · 2016
1/1 SYR4
Gross Beta Particle Activity
3.202 pCi/L
No EPA limit set
Main supplier: HICKSVILLE WD · 48,000 people · 2016
1/1 SYR4
1,2-Dichloroethane
3.2 µg/L 64%
of the EPA limit 5 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Bromoform
2.9 µg/L
No EPA limit set
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Dibromochloromethane
2.06 µg/L
No EPA limit set
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Vinyl Chloride
1.925 µg/L 96%
of the EPA limit 2 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Gross Alpha, Excl. Radon And U
1.83 pCi/L 12%
of the EPA limit 15 pCi/L
Main supplier: HICKSVILLE WD · 48,000 people · 2016
1/1 SYR4
1,2-Dichloropropane
1.58 µg/L 32%
of the EPA limit 5 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Dibromoacetic Acid
1.56 µg/L
No EPA limit set
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Combined Uranium
1.4155 µg/L 4.7%
of the EPA limit 30 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2016
1/1 SYR4
Antimony, Total
1.1571 µg/L 19%
of the EPA limit 6 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
trans-1,2-Dichloroethylene
0.7525 µg/L 0.8%
of the EPA limit 100 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Benzene
0.5875 µg/L 12%
of the EPA limit 5 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Thallium, Total
0.4400 µg/L 22%
of the EPA limit 2 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Mercury
0.3000 µg/L 15%
of the EPA limit 2 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Heptachlor Epoxide
0.0220 µg/L 11%
of the EPA limit 0.2000 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Ethylene Dibromide
0.0200 µg/L 40%
of the EPA limit 0.0500 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
1,2-DIBROMO-3-CHLOROPROPANE
0.0100 µg/L 5%
of the EPA limit 0.2000 µg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2019
1/1 SYR4
Pfpea
0.0033 µg/L
No EPA limit set
Main supplier: HICKSVILLE WD · 48,000 people · 2025
1/1 UCMR-5
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
Main supplier: HICKSVILLE WD · 48,000 people · 2023
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 11801

SupplierStatePopulation served
HICKSVILLE WD NY 48,000

Frequently asked questions about ZIP 11801 tap water

Is the tap water in ZIP 11801 safe to drink?

EPA testing detected 37 contaminants across the water suppliers serving ZIP 11801. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 11801?

1 public water supplier report EPA drinking-water monitoring for ZIP 11801. Each is listed above with its population served.

What contaminants are in ZIP 11801's water?

EPA monitoring detected Nitrate-Nitrite, Nitrate, Copper, Fluoride, cis-1,2-Dichloroethylene, and others across this ZIP's suppliers. The full list with levels and sources is above.