← Oyster Bay, NY

Tap water quality report

ZIP 11791 — Oyster Bay, NY

EPA monitoring across the 1 water supplier serving ZIP 11791 in Oyster Bay, NY detected 41 contaminants. A detection doesn't automatically mean the water is unsafe — see the highest level found below, with the EPA limit for each.

1
water supplier
58,000
people served
41
contaminants found

What was found in ZIP 11791

The highest level seen across the suppliers serving this ZIP, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
12100 µg/L 121%
of the EPA limit, in the worst sample — 10000 µg/L
1/1 SYR4
Nitrate-Nitrite
9910 µg/L 99%
of the EPA limit 10000 µg/L
1/1 SYR4
Copper
420 µg/L 32%
of the EPA limit 1300 µg/L
1/1 SYR4
Fluoride
140 µg/L 3.5%
of the EPA limit 4000 µg/L
1/1 SYR4
Nitrite
60 µg/L 6%
of the EPA limit 1000 µg/L
1/1 SYR4
Barium
50 µg/L 2.5%
of the EPA limit 2000 µg/L
1/1 SYR4
1,1-Dichloroethylene
21.1 µg/L 301%
of the EPA limit, in the worst sample — 7 µg/L
1/1 SYR4
Trichloroethylene
19.7 µg/L 394%
of the EPA limit, in the worst sample — 5 µg/L
1/1 SYR4
Chromium
16 µg/L 16%
of the EPA limit 100 µg/L
1/1 SYR4
Arsenic
11 µg/L 110%
of the EPA limit, in the worst sample — 10 µg/L
1/1 SYR4
Carbon Tetrachloride
9.1 µg/L 182%
of the EPA limit, in the worst sample — 5 µg/L
1/1 SYR4
Lead
9.1 µg/L 61%
of the EPA limit 15 µg/L
1/1 SYR4
1,1,1-Trichloroethane
8.8 µg/L 4.4%
of the EPA limit 200 µg/L
1/1 SYR4
Tetrachloroethylene
6 µg/L 120%
of the EPA limit, in the worst sample — 5 µg/L
1/1 SYR4
1,2-Dichloropropane
4.5 µg/L 90%
of the EPA limit 5 µg/L
1/1 SYR4
1,1,2-Trichloroethane
4.44 µg/L 89%
of the EPA limit 5 µg/L
1/1 SYR4
TTHM
4.1 µg/L 5.1%
of the EPA limit 80 µg/L
1/1 SYR4
Simazine
3 µg/L 75%
of the EPA limit 4 µg/L
1/1 SYR4
Selenium
2.9 µg/L 5.8%
of the EPA limit 50 µg/L
1/1 SYR4
cis-1,2-Dichloroethylene
2.9 µg/L 4.1%
of the EPA limit 70 µg/L
1/1 SYR4
Bromoform
2.6 µg/L
No EPA limit set
1/1 SYR4
Combined Radium (-226 And -228)
2.13 pCi/L 43%
of the EPA limit 5 pCi/L
1/1 SYR4
Antimony, Total
1.77 µg/L 30%
of the EPA limit 6 µg/L
1/1 SYR4
Gross Beta Particle Activity
1.41 pCi/L
No EPA limit set
1/1 SYR4
1,2-Dichloroethane
1.3 µg/L 26%
of the EPA limit 5 µg/L
1/1 SYR4
Dibromochloromethane
1.3 µg/L
No EPA limit set
1/1 SYR4
Toluene
1.1 µg/L 0.1%
of the EPA limit 1000 µg/L
1/1 SYR4
Combined Uranium
0.8200 µg/L 2.7%
of the EPA limit 30 µg/L
1/1 SYR4
Chloroform
0.8000 µg/L
No EPA limit set
1/1 SYR4
Thallium, Total
0.7900 µg/L 40%
of the EPA limit 2 µg/L
1/1 SYR4
Ethylbenzene
0.6000 µg/L 0.1%
of the EPA limit 700 µg/L
1/1 SYR4
Atrazine
0.5960 µg/L 20%
of the EPA limit 3 µg/L
1/1 SYR4
Bromodichloromethane
0.5800 µg/L
No EPA limit set
1/1 SYR4
Beryllium, Total
0.3400 µg/L 8.5%
of the EPA limit 4 µg/L
1/1 SYR4
Pfba
0.0670 µg/L
No EPA limit set
1/1 UCMR-5
Pentachlorophenol
0.0570 µg/L 5.7%
of the EPA limit 1 µg/L
1/1 SYR4
Pfpea
0.0370 µg/L
No EPA limit set
1/1 UCMR-5
Pfhxa
0.0180 µg/L
No EPA limit set
1/1 UCMR-5
6:2 Fts
0.0099 µg/L
No EPA limit set
1/1 UCMR-5
Pfhpa
0.0046 µg/L
No EPA limit set
1/1 UCMR-5
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 11791

SupplierStatePopulation served
JERICHO WD NY 58,000

Frequently asked questions about ZIP 11791 tap water

Is the tap water in ZIP 11791 safe to drink?

EPA testing detected 41 contaminants across the water suppliers serving ZIP 11791. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 11791?

1 public water supplier report EPA drinking-water monitoring for ZIP 11791. Each is listed above with its population served.

What contaminants are in ZIP 11791's water?

EPA monitoring detected Nitrate, Nitrate-Nitrite, Copper, Fluoride, Nitrite, and others across this ZIP's suppliers. The full list with levels and sources is above.