← Texas

Tap water quality report

City of Cushing

EPA monitoring tested this supplier for 80 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
25
detected
1,007
people served
34
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Nacogdoches

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

34
health-based violations
84
violations on file
6
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2024-10-17
TT Health-based Unaddressed 2024-10-17
TT Health-based Unaddressed 2024-10-17
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-01-01 → 2018-03-31
MCL Health-based Resolved 2018-01-01 → 2018-03-31
MCL Health-based Resolved 2018-01-01 → 2018-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
37.5 µg/L
No EPA limit set
54/54 SYR4 2012–2019
Chloroform
114 µg/L
No EPA limit set
54/54 SYR4 2012–2019
Dichloroacetic Acid
25.7 µg/L
No EPA limit set
42/42 SYR4 2012–2019
TTHM
162 µg/L 203%
of the EPA limit, in the worst sample — 80 µg/L
42/42 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
74.7 µg/L 125%
of the EPA limit, in the worst sample — 60 µg/L
42/42 SYR4 2012–2019
Trichloroacetic Acid
36.5 µg/L
No EPA limit set
42/42 SYR4 2012–2019
Dibromochloromethane
9.64 µg/L
No EPA limit set
35/54 SYR4 2012–2019
Copper
1280 µg/L 98%
of the EPA limit 1300 µg/L
31/33 SYR4 2012–2019
Nitrate
44 µg/L 0.4%
of the EPA limit 10000 µg/L
26/30 SYR4 2012–2019
Monochloroacetic Acid
19.4 µg/L
No EPA limit set
24/42 SYR4 2012–2019
Lead
31 µg/L 207%
of the EPA limit, in the worst sample — 15 µg/L
16/33 SYR4 2012–2019
Bromate
79 µg/L 790%
of the EPA limit, in the worst sample — 10 µg/L
14/86 SYR4 2013–2019
Dibromoacetic Acid
20.8 µg/L
No EPA limit set
9/42 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
7/7 LCR 2023
Fluoride
250 µg/L 6.3%
of the EPA limit 4000 µg/L
6/6 SYR4 2012–2018
Barium
34 µg/L 1.7%
of the EPA limit 2000 µg/L
5/5 SYR4 2012–2018
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
4/4 SYR4 2012–2018
Dalapon
2.02 µg/L 1%
of the EPA limit 200 µg/L
4/18 SYR4 2012–2019
Chromium
3.2 µg/L 3.2%
of the EPA limit 100 µg/L
3/5 SYR4 2012–2018
Nitrate-Nitrite
42.6 µg/L 0.4%
of the EPA limit 10000 µg/L
3/3 SYR4 2014–2019
Cyanide
6.14 µg/L 3.1%
of the EPA limit 200 µg/L
2/4 SYR4 2014–2017
Arsenic
1.2 µg/L 12%
of the EPA limit 10 µg/L
1/5 SYR4 2012–2018
Beryllium, Total
0.0820 µg/L 2.1%
of the EPA limit 4 µg/L
1/5 SYR4 2012–2018
Thallium, Total
0.2440 µg/L 12%
of the EPA limit 2 µg/L
1/5 SYR4 2012–2018
Xylenes, Total
0.5800 µg/L 0%
of the EPA limit 10000 µg/L
1/12 SYR4 2012–2019
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
STEWART, ROSEY M
Phone
936-326-4665
Email
ctycush@gmail.com

Frequently asked questions about City of Cushing

Is City of Cushing tap water safe to drink?

EPA monitoring detected 25 contaminants in City of Cushing's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Cushing's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does City of Cushing serve?

City of Cushing reports serving 1,007 people in Texas, per its EPA record.

Has City of Cushing had any water quality violations?

The EPA has 84 violations on file for City of Cushing, of which 34 are health-based (a contaminant limit or required treatment was breached) and 6 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.