← Texas

Tap water quality report

Wellborn Sud

EPA monitoring tested this supplier for 110 contaminants and detected 32. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
32
detected
25,092
people served
31
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Brazos

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

31
health-based violations
75
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2014-07-01 → 2014-09-30
MCL Health-based Resolved 2014-04-01 → 2014-06-30
MCL Health-based Resolved 2014-04-01 → 2014-06-30
MCL Health-based Resolved 2014-04-01 → 2014-06-30
MCL Health-based Resolved 2014-04-01 → 2014-06-30
MCL Health-based Resolved 2014-04-01 → 2014-06-30
MCL Health-based Resolved 2014-04-01 → 2014-06-30
MCL Health-based Resolved 2014-04-01 → 2014-06-30
MCL Health-based Resolved 2014-01-01 → 2014-03-31
MCL Health-based Resolved 2014-01-01 → 2014-03-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfpea 0.0037 µg/L 2/13 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
411.4 µg/L 32%
of the EPA limit 1300 µg/L
worst single sample: 16800 µg/L
223/225 SYR4 2012–2018
Nitrate
5684 µg/L 57%
of the EPA limit 10000 µg/L
worst single sample: 6920 µg/L
152/154 SYR4 2012–2019
Dibromochloromethane
27.29 µg/L
No EPA limit set
worst single sample: 62.6 µg/L
139/154 SYR4 2012–2019
Bromodichloromethane
28.04 µg/L
No EPA limit set
worst single sample: 78.1 µg/L
133/154 SYR4 2012–2019
Chlorite
724.5 µg/L 72%
of the EPA limit 1000 µg/L
worst single sample: 1074 µg/L
132/201 SYR4 2013–2019
Lead
9.634 µg/L 64%
of the EPA limit 15 µg/L
worst single sample: 123 µg/L
132/225 SYR4 2012–2018
Bromoform
24.34 µg/L
No EPA limit set
worst single sample: 34.1 µg/L
129/154 SYR4 2012–2019
Chloroform
65 µg/L
No EPA limit set
worst single sample: 195 µg/L
121/154 SYR4 2012–2019
TTHM
108.23 µg/L 135%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 234 µg/L
119/122 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
76.9 µg/L 128%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 292.2 µg/L
112/121 SYR4 2012–2019
Dibromoacetic Acid
10.09 µg/L
No EPA limit set
worst single sample: 23.5 µg/L
108/121 SYR4 2012–2019
Dichloroacetic Acid
51.9 µg/L
No EPA limit set
worst single sample: 84.2 µg/L
81/121 SYR4 2012–2019
Trichloroacetic Acid
42.325 µg/L
No EPA limit set
worst single sample: 169 µg/L
62/121 SYR4 2012–2019
Barium
161.1 µg/L 8.1%
of the EPA limit 2000 µg/L
worst single sample: 163 µg/L
20/20 SYR4 2012–2019
Fluoride
1974 µg/L 49%
of the EPA limit 4000 µg/L
worst single sample: 1990 µg/L
17/20 SYR4 2012–2019
Lead
0.0015 mg/L 9.9%
of the EPA limit 0.0150 mg/L
15/15 LCR 2024
Monochloroacetic Acid
15.69 µg/L
No EPA limit set
worst single sample: 39 µg/L
15/121 SYR4 2012–2019
Nitrate-Nitrite
4889.5 µg/L 49%
of the EPA limit 10000 µg/L
worst single sample: 6300 µg/L
14/14 SYR4 2012–2019
Lithium
45.7 µg/L
No EPA limit set
13/14 UCMR-5 2025
Monobromoacetic Acid
4.2 µg/L
No EPA limit set
worst single sample: 5.6 µg/L
8/121 SYR4 2012–2019
Chromium
12.748 µg/L 13%
of the EPA limit 100 µg/L
worst single sample: 14.5 µg/L
4/20 SYR4 2012–2019
Combined Radium (-226 And -228)
2.01 pCi/L 40%
of the EPA limit 5 pCi/L
worst single sample: 2.1 pCi/L
4/4 SYR4 2013–2019
Arsenic
3.39 µg/L 34%
of the EPA limit 10 µg/L
worst single sample: 3.5 µg/L
3/20 SYR4 2012–2019
Selenium
4.91 µg/L 9.8%
of the EPA limit 50 µg/L
worst single sample: 5.1 µg/L
3/20 SYR4 2012–2019
Simazine
0.1380 µg/L 3.5%
of the EPA limit 4 µg/L
worst single sample: 0.1400 µg/L
3/39 SYR4 2012–2019
Xylenes, Total
0.9900 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 1 µg/L
3/33 SYR4 2012–2019
Atrazine
0.1195 µg/L 4%
of the EPA limit 3 µg/L
worst single sample: 0.1200 µg/L
2/39 SYR4 2012–2019
Gross Beta Particle Activity
4.895 pCi/L
No EPA limit set
worst single sample: 4.9 pCi/L
2/14 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
1.6 µg/L 27%
of the EPA limit 6 µg/L
1/38 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
4.6 pCi/L 31%
of the EPA limit 15 pCi/L
1/10 SYR4 2013–2019
Nitrite
10 µg/L 1%
of the EPA limit 1000 µg/L
1/17 SYR4 2012–2019
78 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MASSEY, JAMES
Phone
979-690-9799

Frequently asked questions about Wellborn Sud

Is Wellborn Sud tap water safe to drink?

EPA monitoring detected 32 contaminants in Wellborn Sud's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Wellborn Sud's water?

EPA monitoring detected Copper, Nitrate, Dibromochloromethane, Bromodichloromethane, Chlorite, and others. The full list with the level and data source for each is above.

How many people does Wellborn Sud serve?

Wellborn Sud reports serving 25,092 people in Texas, per its EPA record.

Has Wellborn Sud had any water quality violations?

The EPA has 75 violations on file for Wellborn Sud, of which 31 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.