← Pennsylvania

Tap water quality report

Lca Upper Milford Central Div

EPA monitoring tested this supplier for 80 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
18
detected
256
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Lehigh

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
28
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2023-06-01 → 2023-06-30
MR Monitoring Resolved 2023-06-01 → 2023-06-30
MR Monitoring Resolved 2023-06-01 → 2023-06-30
MR Monitoring Resolved 2023-06-01 → 2023-06-30
MR Monitoring Resolved 2020-11-01 → 2020-11-30
MR Monitoring Resolved 2020-11-01 → 2020-11-30
MR Monitoring Resolved 2020-11-01 → 2020-11-30
MR Monitoring Resolved 2020-11-01 → 2020-11-30
MR Monitoring Resolved 2012-09-01 → 2012-09-30
MR Monitoring Resolved 2012-09-01 → 2012-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
7050 µg/L 71%
of the EPA limit 10000 µg/L
worst single sample: 8420 µg/L
128/128 SYR4 2012–2019
Copper
742.2 µg/L 57%
of the EPA limit 1300 µg/L
worst single sample: 829 µg/L
15/15 SYR4 2013–2019
Lead
5.6 µg/L 37%
of the EPA limit 15 µg/L
worst single sample: 8 µg/L
13/15 SYR4 2013–2019
Atrazine
0.2750 µg/L 9.2%
of the EPA limit 3 µg/L
worst single sample: 0.3000 µg/L
6/19 SYR4 2012–2019
Barium
75.6 µg/L 3.8%
of the EPA limit 2000 µg/L
worst single sample: 81 µg/L
4/6 SYR4 2012–2018
Bromodichloromethane
10.46 µg/L
No EPA limit set
worst single sample: 10.7 µg/L
4/4 SYR4 2012–2018
Bromoform
2.525 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
4/4 SYR4 2012–2018
Chloroform
12.675 µg/L
No EPA limit set
worst single sample: 13.2 µg/L
4/4 SYR4 2012–2018
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
4/6 SYR4 2012–2018
Combined Uranium
5.78195 µg/L 19%
of the EPA limit 30 µg/L
worst single sample: 5.811 µg/L
4/4 SYR4 2013–2019
Dibromochloromethane
6.95 µg/L
No EPA limit set
worst single sample: 7.1 µg/L
4/4 SYR4 2012–2018
TTHM
30.48 µg/L 38%
of the EPA limit 80 µg/L
worst single sample: 30.9 µg/L
4/4 SYR4 2012–2018
Lead
0.0040 mg/L 27%
of the EPA limit 0.0150 mg/L
3/3 LCR 1996
Total Haloacetic Acids (HAA5)
10.098 µg/L 17%
of the EPA limit 60 µg/L
worst single sample: 10.6 µg/L
3/4 SYR4 2012–2018
Di(2-ethylhexyl) Adipate
1.8 µg/L 0.5%
of the EPA limit 400 µg/L
1/18 SYR4 2012–2019
Dibromoacetic Acid
1.4 µg/L
No EPA limit set
1/1 SYR4 2018
Dichloroacetic Acid
7.89 µg/L
No EPA limit set
1/1 SYR4 2018
Trichloroacetic Acid
1.36 µg/L
No EPA limit set
1/1 SYR4 2018
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ANDREW MOORE
Phone
610-398-2503

Frequently asked questions about Lca Upper Milford Central Div

Is Lca Upper Milford Central Div tap water safe to drink?

EPA monitoring detected 18 contaminants in Lca Upper Milford Central Div's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lca Upper Milford Central Div's water?

EPA monitoring detected Nitrate, Copper, Lead, Atrazine, Barium, and others. The full list with the level and data source for each is above.

How many people does Lca Upper Milford Central Div serve?

Lca Upper Milford Central Div reports serving 256 people in Pennsylvania, per its EPA record.

Has Lca Upper Milford Central Div had any water quality violations?

The EPA has 28 violations on file for Lca Upper Milford Central Div, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.