← New York

Tap water quality report

Hunters Creek Mobile Home Park

EPA monitoring tested this supplier for 73 contaminants and detected 25. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

73
contaminants tested
25
detected
150
people served
29
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Erie

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

29
health-based violations
1,582
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2002-04-01 → 2002-06-30
MCL Health-based Resolved 2002-04-01 → 2002-06-30
MCL Health-based Resolved 2002-04-01 → 2002-06-30
MCL Health-based Resolved 2001-04-01 → 2001-06-30
MCL Health-based Resolved 2001-04-01 → 2001-06-30
MCL Health-based Resolved 2001-01-01 → 2001-03-31
MCL Health-based Resolved 2001-01-01 → 2001-03-31
MCL Health-based Resolved 2001-01-01 → 2001-03-31
MCL Health-based Resolved 2000-07-01 → 2000-09-30
MCL Health-based Resolved 2000-07-01 → 2000-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Benzene
1.9 µg/L 38%
of the EPA limit 5 µg/L
40/96 SYR4 2012–2019
TTHM
34 µg/L 43%
of the EPA limit 80 µg/L
24/28 SYR4 2014–2019
Bromoform
12 µg/L
No EPA limit set
23/30 SYR4 2014–2019
Dibromoacetic Acid
7.1 µg/L
No EPA limit set
23/29 SYR4 2014–2019
Dibromochloromethane
13 µg/L
No EPA limit set
22/30 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
127 µg/L 212%
of the EPA limit, in the worst sample — 60 µg/L
22/26 SYR4 2014–2019
Bromodichloromethane
13 µg/L
No EPA limit set
21/30 SYR4 2014–2019
Nitrate
74 µg/L 0.7%
of the EPA limit 10000 µg/L
14/36 SYR4 2013–2019
Trichloroacetic Acid
11 µg/L
No EPA limit set
11/29 SYR4 2014–2019
1,2-Dichloropropane
0.7000 µg/L 14%
of the EPA limit 5 µg/L
10/96 SYR4 2012–2019
Chloroform
2.4 µg/L
No EPA limit set
10/30 SYR4 2014–2019
Barium
1100 µg/L 55%
of the EPA limit 2000 µg/L
8/8 SYR4 2013–2019
Dichloroacetic Acid
4 µg/L
No EPA limit set
8/27 SYR4 2014–2019
Fluoride
200 µg/L 5%
of the EPA limit 4000 µg/L
7/8 SYR4 2013–2019
1,2-Dichloroethane
0.2500 µg/L 5%
of the EPA limit 5 µg/L
6/96 SYR4 2012–2019
Toluene
0.6000 µg/L 0.1%
of the EPA limit 1000 µg/L
6/96 SYR4 2012–2019
Combined Radium (-226 And -228)
4.4 pCi/L 88%
of the EPA limit 5 pCi/L
5/5 SYR4 2013–2019
Lead
0.00090 mg/L 6%
of the EPA limit 0.0150 mg/L
5/5 LCR 2032
Monobromoacetic Acid
110 µg/L
No EPA limit set
5/29 SYR4 2014–2019
Antimony, Total
2.1 µg/L 35%
of the EPA limit 6 µg/L
1/8 SYR4 2013–2019
Combined Uranium
4 µg/L 13%
of the EPA limit 30 µg/L
1/1 SYR4 2013
Gross Alpha, Excl. Radon And U
1 pCi/L 6.7%
of the EPA limit 15 pCi/L
1/1 SYR4 2013
Gross Beta Particle Activity
1.4 pCi/L
No EPA limit set
1/1 SYR4 2019
Monochloroacetic Acid
0.5000 µg/L
No EPA limit set
1/29 SYR4 2014–2019
Selenium
0.7000 µg/L 1.4%
of the EPA limit 50 µg/L
1/8 SYR4 2013–2019
48 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene2,4,5-TP2,4-DArsenicAtrazineBhc-GammaBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BENEDICTO, ANTHONY
Phone
716-572-1666

Frequently asked questions about Hunters Creek Mobile Home Park

Is Hunters Creek Mobile Home Park tap water safe to drink?

EPA monitoring detected 25 contaminants in Hunters Creek Mobile Home Park's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Hunters Creek Mobile Home Park's water?

EPA monitoring detected Benzene, TTHM, Bromoform, Dibromoacetic Acid, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Hunters Creek Mobile Home Park serve?

Hunters Creek Mobile Home Park reports serving 150 people in New York, per its EPA record.

Has Hunters Creek Mobile Home Park had any water quality violations?

The EPA has 1582 violations on file for Hunters Creek Mobile Home Park, of which 29 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.