EPA monitoring detected 32 contaminants across the 3 water suppliers serving Holland. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

3
water suppliers
1,860
people served
32
contaminants found

What was found in Holland's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Barium
1680 µg/L 84%
of the EPA limit 2000 µg/L
3/3 SYR4
Fluoride
200 µg/L 5%
of the EPA limit 4000 µg/L
3/3 SYR4
Total Haloacetic Acids (HAA5)
127 µg/L 212%
of the EPA limit, in the worst sample — 60 µg/L
3/3 SYR4
Monobromoacetic Acid
110 µg/L
No EPA limit set
2/3 SYR4
Nitrate
74 µg/L 0.7%
of the EPA limit 10000 µg/L
3/3 SYR4
TTHM
34 µg/L 43%
of the EPA limit 80 µg/L
3/3 SYR4
Bromodichloromethane
13 µg/L
No EPA limit set
2/3 SYR4
Dibromochloromethane
13 µg/L
No EPA limit set
2/3 SYR4
Bromoform
12 µg/L
No EPA limit set
2/3 SYR4
Trichloroacetic Acid
11 µg/L
No EPA limit set
2/3 SYR4
Dibromoacetic Acid
7.1 µg/L
No EPA limit set
2/3 SYR4
Cyanide
5 µg/L 2.5%
of the EPA limit 200 µg/L
1/3 SYR4
Combined Radium (-226 And -228)
4.4 pCi/L 88%
of the EPA limit 5 pCi/L
3/3 SYR4
Combined Uranium
4 µg/L 13%
of the EPA limit 30 µg/L
3/3 SYR4
Dichloroacetic Acid
4 µg/L
No EPA limit set
1/3 SYR4
Selenium
4 µg/L 8%
of the EPA limit 50 µg/L
2/3 SYR4
Gross Beta Particle Activity
2.5 pCi/L
No EPA limit set
2/3 SYR4
Chloroform
2.4 µg/L
No EPA limit set
1/3 SYR4
Antimony, Total
2.1 µg/L 35%
of the EPA limit 6 µg/L
2/3 SYR4
Gross Alpha, Excl. Radon And U
1.95 pCi/L 13%
of the EPA limit 15 pCi/L
3/3 SYR4
Benzene
1.9 µg/L 38%
of the EPA limit 5 µg/L
1/3 SYR4
Chromium
1.1 µg/L 1.1%
of the EPA limit 100 µg/L
1/3 SYR4
1,2-Dichloropropane
0.7000 µg/L 14%
of the EPA limit 5 µg/L
1/3 SYR4
Toluene
0.6000 µg/L 0.1%
of the EPA limit 1000 µg/L
1/3 SYR4
Monochloroacetic Acid
0.5000 µg/L
No EPA limit set
1/3 SYR4
Arsenic
0.4000 µg/L 4%
of the EPA limit 10 µg/L
1/3 SYR4
1,2-Dichloroethane
0.2500 µg/L 5%
of the EPA limit 5 µg/L
1/3 SYR4
Beryllium, Total
0.2000 µg/L 5%
of the EPA limit 4 µg/L
1/3 SYR4
Mercury
0.0800 µg/L 4%
of the EPA limit 2 µg/L
1/3 SYR4
Cadmium
0.0700 µg/L 1.4%
of the EPA limit 5 µg/L
1/3 SYR4
Thallium, Total
0.0400 µg/L 2%
of the EPA limit 2 µg/L
1/3 SYR4
Lead
0.0032 mg/L 21%
of the EPA limit 0.0150 mg/L
3/3 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Holland

Frequently asked questions about Holland tap water

Is Holland tap water safe to drink?

EPA testing detected 32 contaminants in the water serving Holland. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Holland?

3 public water suppliers report drinking-water monitoring for Holland, New York to the EPA. Each is listed above with its population served.

What contaminants are in Holland's water?

The contaminants EPA monitoring detected in Holland include Barium, Fluoride, Total Haloacetic Acids (HAA5), Monobromoacetic Acid, Nitrate. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.