← Louisiana

Tap water quality report

Jones Mcginty Water

EPA monitoring tested this supplier for 81 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

81
contaminants tested
23
detected
696
people served
641
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Morehouse Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

641
health-based violations
773
violations on file
91
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-04-01 → 2025-06-30
MCL Health-based Archived 2025-04-01 → 2025-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
366 µg/L 458%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 451 µg/L
61/62 SYR4 2012–2019
Chloroform
6.915 µg/L
No EPA limit set
worst single sample: 36.9 µg/L
60/62 SYR4 2012–2019
Bromodichloromethane
22.93 µg/L
No EPA limit set
worst single sample: 25.8 µg/L
58/62 SYR4 2012–2019
Dibromochloromethane
101.2 µg/L
No EPA limit set
worst single sample: 111 µg/L
57/62 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
66.26 µg/L 110%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 84.6 µg/L
57/62 SYR4 2012–2019
Dibromoacetic Acid
55.175 µg/L
No EPA limit set
worst single sample: 71.5 µg/L
56/62 SYR4 2012–2019
Bromoform
241.4 µg/L
No EPA limit set
worst single sample: 310 µg/L
55/62 SYR4 2012–2019
Trichloroacetic Acid
3.94 µg/L
No EPA limit set
worst single sample: 5.8 µg/L
53/62 SYR4 2012–2019
Dichloroacetic Acid
4.14 µg/L
No EPA limit set
worst single sample: 4.9 µg/L
47/62 SYR4 2012–2019
Monobromoacetic Acid
5.075 µg/L
No EPA limit set
worst single sample: 5.6 µg/L
34/62 SYR4 2012–2019
Copper
400 µg/L 31%
of the EPA limit 1300 µg/L
worst single sample: 500 µg/L
26/36 SYR4 2013–2019
Lead
3.3 µg/L 22%
of the EPA limit 15 µg/L
worst single sample: 5 µg/L
18/36 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
10/10 LCR 2025
Fluoride
668 µg/L 17%
of the EPA limit 4000 µg/L
worst single sample: 700 µg/L
9/9 SYR4 2012–2018
Monochloroacetic Acid
10.46 µg/L
No EPA limit set
worst single sample: 11.6 µg/L
7/62 SYR4 2012–2019
Barium
120 µg/L 6%
of the EPA limit 2000 µg/L
6/9 SYR4 2012–2018
Combined Radium (-226 And -228)
0.9842 pCi/L 20%
of the EPA limit 5 pCi/L
worst single sample: 1.02 pCi/L
5/6 SYR4 2015–2018
Gross Beta Particle Activity
2.86 pCi/L
No EPA limit set
worst single sample: 3 pCi/L
5/9 SYR4 2012–2018
Arsenic
1.85 µg/L 19%
of the EPA limit 10 µg/L
worst single sample: 2 µg/L
4/9 SYR4 2012–2018
Di(2-ethylhexyl) Phthalate
1.295 µg/L 22%
of the EPA limit 6 µg/L
worst single sample: 1.4 µg/L
4/9 SYR4 2012–2018
Dalapon
9.136 µg/L 4.6%
of the EPA limit 200 µg/L
1/9 SYR4 2012–2018
Di(2-ethylhexyl) Adipate
0.6900 µg/L 0.2%
of the EPA limit 400 µg/L
1/9 SYR4 2012–2018
Gross Alpha, Excl. Radon And U
3.03 pCi/L 20%
of the EPA limit 15 pCi/L
1/5 SYR4 2012–2016
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitrate-NitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
STUTTS, JUSTIN
Phone
318-376-0800
Email
justinstutts3@gmail.com

Frequently asked questions about Jones Mcginty Water

Is Jones Mcginty Water tap water safe to drink?

EPA monitoring detected 23 contaminants in Jones Mcginty Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Jones Mcginty Water's water?

EPA monitoring detected TTHM, Chloroform, Bromodichloromethane, Dibromochloromethane, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Jones Mcginty Water serve?

Jones Mcginty Water reports serving 696 people in Louisiana, per its EPA record.

Has Jones Mcginty Water had any water quality violations?

The EPA has 773 violations on file for Jones Mcginty Water, of which 641 are health-based (a contaminant limit or required treatment was breached) and 91 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.