← Louisiana

Tap water quality report

City of Rayne Water

EPA monitoring tested this supplier for 111 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

111
contaminants tested
23
detected
10,908
people served
12
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Acadia Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

12
health-based violations
29
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2012-09-01 → 2012-09-30
MCL Health-based Resolved 2012-09-01 → 2012-09-30
MCL Health-based Resolved 2012-09-01 → 2012-09-30
MCL Health-based Resolved 2012-09-01 → 2012-09-30
MCL Health-based Archived 1997-08-01 → 1997-08-31
MCL Health-based Archived 1997-08-01 → 1997-08-31
MCL Health-based Archived 1997-08-01 → 1997-08-31
MCL Health-based Archived 1995-03-01 → 1995-03-31
MCL Health-based Archived 1995-03-01 → 1995-03-31
MCL Health-based Archived 1994-10-01 → 1994-10-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
500 µg/L 38%
of the EPA limit 1300 µg/L
28/45 SYR4 2014–2018
Nitrate-Nitrite
2000 µg/L 20%
of the EPA limit 10000 µg/L
20/34 SYR4 2012–2019
Lead
4 µg/L 27%
of the EPA limit 15 µg/L
18/45 SYR4 2014–2018
Chloroform
17 µg/L
No EPA limit set
14/14 SYR4 2013–2019
Dichloroacetic Acid
11 µg/L
No EPA limit set
14/14 SYR4 2013–2019
TTHM
51.1 µg/L 64%
of the EPA limit 80 µg/L
14/14 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
27 µg/L 45%
of the EPA limit 60 µg/L
14/14 SYR4 2013–2019
Trichloroacetic Acid
9.9 µg/L
No EPA limit set
13/14 SYR4 2013–2019
Bromodichloromethane
17 µg/L
No EPA limit set
12/14 SYR4 2013–2019
Bromoform
7.7 µg/L
No EPA limit set
12/14 SYR4 2013–2019
Dibromoacetic Acid
5.4 µg/L
No EPA limit set
12/14 SYR4 2013–2019
Dibromochloromethane
16.3 µg/L
No EPA limit set
12/14 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
11/11 LCR 2023
Barium
1000 µg/L 50%
of the EPA limit 2000 µg/L
7/10 SYR4 2012–2018
Fluoride
200 µg/L 5%
of the EPA limit 4000 µg/L
7/8 SYR4 2012–2018
Combined Radium (-226 And -228)
1.87 pCi/L 37%
of the EPA limit 5 pCi/L
5/5 SYR4 2015–2018
Gross Beta Particle Activity
4.51 pCi/L
No EPA limit set
4/8 SYR4 2012–2018
Monobromoacetic Acid
0.9500 µg/L
No EPA limit set
4/14 SYR4 2013–2019
Monochloroacetic Acid
7.2 µg/L
No EPA limit set
4/14 SYR4 2013–2019
Di(2-ethylhexyl) Phthalate
4.23 µg/L 71%
of the EPA limit 6 µg/L
3/8 SYR4 2012–2018
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
2/8 SYR4 2012–2018
Lithium
17.4 µg/L
No EPA limit set
2/2 UCMR-5 2025
Di(2-ethylhexyl) Adipate
4.07 µg/L 1%
of the EPA limit 400 µg/L
1/8 SYR4 2012–2018
88 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ROBICHAUX, CHARLES
Phone
337-344-6603
Email
MAYOR@RAYNE.ORG

Frequently asked questions about City of Rayne Water

Is City of Rayne Water tap water safe to drink?

EPA monitoring detected 23 contaminants in City of Rayne Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Rayne Water's water?

EPA monitoring detected Copper, Nitrate-Nitrite, Lead, Chloroform, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does City of Rayne Water serve?

City of Rayne Water reports serving 10,908 people in Louisiana, per its EPA record.

Has City of Rayne Water had any water quality violations?

The EPA has 29 violations on file for City of Rayne Water, of which 12 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.