Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| Other | Monitoring | Resolved | 2025-07-01 |
| Other | Monitoring | Resolved | 2025-07-01 |
| MR | Monitoring | Resolved | 2023-10-01 |
| MR | Monitoring | Resolved | 2023-10-01 |
| MR | Monitoring | Resolved | 2023-10-01 |
| Other | Monitoring | Resolved | 2022-07-01 |
| Other | Monitoring | Resolved | 2022-07-01 |
| Other | Monitoring | Resolved | 2021-07-01 |
| Other | Monitoring | Resolved | 2021-07-01 |
| Other | Monitoring | Resolved | 2010-07-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 127.5 µg/L 9.8% of the EPA limit 1300 µg/L
worst single sample: 254 µg/L | 31/41 | SYR4 | 2013–2019 |
| Lead | 209.5 µg/L 1397% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 331 µg/L | 16/41 | SYR4 | 2013–2019 |
| Nitrate | 7504 µg/L 75% of the EPA limit 10000 µg/L | 16/34 | SYR4 | 2012–2019 |
| Lead | 0.0016 mg/L 11% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2025 |
| Nitrate-Nitrite | 7498.89 µg/L 75% of the EPA limit 10000 µg/L
worst single sample: 7504 µg/L | 8/17 | SYR4 | 2012–2019 |
| Bromodichloromethane | 6.078 µg/L No EPA limit set
worst single sample: 6.12 µg/L | 5/5 | SYR4 | 2014–2019 |
| Chloroform | 27.74 µg/L No EPA limit set
worst single sample: 28.3 µg/L | 5/5 | SYR4 | 2014–2019 |
| Combined Radium (-226 And -228) | 0.9906 pCi/L 20% of the EPA limit 5 pCi/L
worst single sample: 0.9920 pCi/L | 5/5 | SYR4 | 2014–2015 |
| Dibromochloromethane | 4.698 µg/L No EPA limit set
worst single sample: 4.79 µg/L | 5/5 | SYR4 | 2014–2019 |
| Barium | 259.151 µg/L 13% of the EPA limit 2000 µg/L
worst single sample: 263.72 µg/L | 4/4 | SYR4 | 2018–2019 |
| Bromoform | 2.363 µg/L No EPA limit set
worst single sample: 2.4 µg/L | 3/5 | SYR4 | 2014–2019 |
| TTHM | 33.516 µg/L 42% of the EPA limit 80 µg/L
worst single sample: 35.6 µg/L | 3/3 | SYR4 | 2014–2019 |
| Dibromoacetic Acid | 1.3638 µg/L No EPA limit set
worst single sample: 1.38 µg/L | 2/2 | SYR4 | 2014–2019 |
| Total Haloacetic Acids (HAA5) | 3.2448 µg/L 5.4% of the EPA limit 60 µg/L
worst single sample: 3.36 µg/L | 2/2 | SYR4 | 2014–2019 |
| Dalapon | 0.7700 µg/L 0.4% of the EPA limit 200 µg/L | 1/4 | SYR4 | 2012–2019 |
| Di(2-ethylhexyl) Adipate | 0.2300 µg/L 0.1% of the EPA limit 400 µg/L | 1/4 | SYR4 | 2012–2019 |
| Di(2-ethylhexyl) Phthalate | 0.2800 µg/L 4.7% of the EPA limit 6 µg/L | 1/4 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 1.98 µg/L No EPA limit set | 1/2 | SYR4 | 2014–2019 |
| Selenium | 1.01 µg/L 2% of the EPA limit 50 µg/L | 1/4 | SYR4 | 2018–2019 |
56 contaminants tested, none detected
Frequently asked questions about Stockley Center
Is Stockley Center tap water safe to drink?
EPA monitoring detected 19 contaminants in Stockley Center's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Stockley Center's water?
EPA monitoring detected Copper, Lead, Nitrate, Lead, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.
How many people does Stockley Center serve?
Stockley Center reports serving 749 people, per its EPA record.
Has Stockley Center had any water quality violations?
The EPA has 18 violations on file for Stockley Center, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.