← California

Tap water quality report

Sugar Pine Homeowners Assoc

EPA monitoring tested this supplier for 42 contaminants and detected 7. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

42
contaminants tested
7
detected
120
people served
10
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Madera

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

10
health-based violations
43
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2024-10-17
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2010-10-01 → 2010-10-31
MCL Health-based Resolved 2010-10-01 → 2010-10-31
MCL Health-based Resolved 2010-10-01 → 2010-10-31
MCL Health-based Resolved 2009-09-01 → 2009-09-30
MCL Health-based Resolved 2009-09-01 → 2009-09-30
MCL Health-based Resolved 2009-09-01 → 2009-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Arsenic
5.295 µg/L 53%
of the EPA limit 10 µg/L
worst single sample: 5.4 µg/L
4/4 SYR4 2014–2017
Lead
0.00080 mg/L 5.3%
of the EPA limit 0.0150 mg/L
3/3 LCR 2027
Combined Uranium
19.3179 µg/L 64%
of the EPA limit 30 µg/L
worst single sample: 19.966 µg/L
2/2 SYR4 2015–2017
Fluoride
178 µg/L 4.5%
of the EPA limit 4000 µg/L
worst single sample: 180 µg/L
2/4 SYR4 2014–2017
Barium
4.2 µg/L 0.2%
of the EPA limit 2000 µg/L
1/4 SYR4 2014–2017
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/4 SYR4 2014–2017
Nitrite
500 µg/L 50%
of the EPA limit 1000 µg/L
1/6 SYR4 2014–2017
35 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalAsbestosAtrazineBenzeneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbon TetrachlorideDichloromethaneEthylbenzeneLassoLeadMercuryNitrateSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MOTT, SUSAN
Phone
559-575-5627
Email
jsherrell@gmail.com

Frequently asked questions about Sugar Pine Homeowners Assoc

Is Sugar Pine Homeowners Assoc tap water safe to drink?

EPA monitoring detected 7 contaminants in Sugar Pine Homeowners Assoc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sugar Pine Homeowners Assoc's water?

EPA monitoring detected Arsenic, Lead, Combined Uranium, Fluoride, Barium, and others. The full list with the level and data source for each is above.

How many people does Sugar Pine Homeowners Assoc serve?

Sugar Pine Homeowners Assoc reports serving 120 people in California, per its EPA record.

Has Sugar Pine Homeowners Assoc had any water quality violations?

The EPA has 43 violations on file for Sugar Pine Homeowners Assoc, of which 10 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.