← California

Tap water quality report

Oakhurst, CA

EPA monitoring detected 25 contaminants across the 10 water suppliers serving Oakhurst. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

10
water suppliers
1,582
people served
25
contaminants found

What was found in Oakhurst's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
3220.5 µg/L 32%
of the EPA limit 10000 µg/L
Highest in the city: WHISPERING PINES MHP · 38 people · 2019
7/10 SYR4
Nitrate-Nitrite
2345 µg/L 23%
of the EPA limit 10000 µg/L
Highest in the city: WHISPERING PINES MHP · 38 people · 2018
4/10 SYR4
Fluoride
2300 µg/L 57%
of the EPA limit 4000 µg/L
Highest in the city: WHISPERING PINES MHP · 38 people · 2018
9/10 SYR4
Nitrite
500 µg/L 50%
of the EPA limit 1000 µg/L
Highest in the city: SUGAR PINE HOMEOWNERS ASSOC · 120 people · 2017
1/10 SYR4
Combined Uranium
228.715 µg/L 762%
of the EPA limit, at the 95th percentile of samples — 30 µg/L
Highest in the city: PIKE RANCH MUTUAL WATER CO · 74 people · 2019
6/10 SYR4
Copper
139.595 µg/L 11%
of the EPA limit 1300 µg/L
Highest in the city: SKY ACRES MUTUAL WATER CORP · 175 people · 2019
5/10 SYR4
Barium
86.3825 µg/L 4.3%
of the EPA limit 2000 µg/L
Highest in the city: SKY ACRES MUTUAL WATER CORP · 175 people · 2019
5/10 SYR4
Arsenic
26.765 µg/L 268%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
Highest in the city: SKY ACRES MUTUAL WATER CORP · 175 people · 2019
7/10 SYR4
Lead
6.64 µg/L 44%
of the EPA limit 15 µg/L
Main supplier: BROADVIEW TERRACE MUTUAL WATER COMPANY · 498 people · 2015
Highest in the city: 15 µg/L — BASS LAKE HEIGHTS MUTUAL WATER · 250 people · 2019
5/10 SYR4
TTHM
7.75 µg/L 9.7%
of the EPA limit 80 µg/L
Main supplier: BROADVIEW TERRACE MUTUAL WATER COMPANY · 498 people · 2019
2/10 SYR4
Beryllium, Total
6.6 µg/L 165%
of the EPA limit, at the 95th percentile of samples — 4 µg/L
Highest in the city: ECCO · 100 people · 2019
1/10 SYR4
Dibromochloromethane
2.9 µg/L
No EPA limit set
Main supplier: BROADVIEW TERRACE MUTUAL WATER COMPANY · 498 people · 2019
Highest in the city: 2.905 µg/L — PIKE RANCH MUTUAL WATER CO · 74 people · 2019
2/10 SYR4
Bromodichloromethane
2.8 µg/L
No EPA limit set
Main supplier: BROADVIEW TERRACE MUTUAL WATER COMPANY · 498 people · 2019
2/10 SYR4
Chromium
2.64 µg/L 2.6%
of the EPA limit 100 µg/L
Highest in the city: SKY ACRES MUTUAL WATER CORP · 175 people · 2019
2/10 SYR4
Chloroform
2.425 µg/L
No EPA limit set
Main supplier: BROADVIEW TERRACE MUTUAL WATER COMPANY · 498 people · 2019
2/10 SYR4
Dibromoacetic Acid
1.2 µg/L
No EPA limit set
Main supplier: BROADVIEW TERRACE MUTUAL WATER COMPANY · 498 people · 2019
Highest in the city: 2.3 µg/L — PIKE RANCH MUTUAL WATER CO · 74 people · 2019
2/10 SYR4
Total Haloacetic Acids (HAA5)
1.2 µg/L 2%
of the EPA limit 60 µg/L
Main supplier: BROADVIEW TERRACE MUTUAL WATER COMPANY · 498 people · 2019
Highest in the city: 2.3 µg/L — PIKE RANCH MUTUAL WATER CO · 74 people · 2019
2/10 SYR4
Dichloromethane
2.1 µg/L 42%
of the EPA limit 5 µg/L
Highest in the city: SKY ACRES MUTUAL WATER CORP · 175 people · 2019
1/10 SYR4
Bromoform
1.3175 µg/L
No EPA limit set
Main supplier: BROADVIEW TERRACE MUTUAL WATER COMPANY · 498 people · 2019
Highest in the city: 2 µg/L — PIKE RANCH MUTUAL WATER CO · 74 people · 2019
2/10 SYR4
Selenium
1.75125 µg/L 3.5%
of the EPA limit 50 µg/L
Highest in the city: SKY ACRES MUTUAL WATER CORP · 175 people · 2019
1/10 SYR4
Antimony, Total
1.092 µg/L 18%
of the EPA limit 6 µg/L
Highest in the city: CEDAR VALLEY MUTUAL WATER CO · 137 people · 2019
1/10 SYR4
Styrene
0.8100 µg/L 0.8%
of the EPA limit 100 µg/L
Highest in the city: YOSEMITE FORKS EST MUTUAL · 110 people · 2019
1/10 SYR4
Toluene
0.6000 µg/L 0.1%
of the EPA limit 1000 µg/L
Highest in the city: SKY ACRES MUTUAL WATER CORP · 175 people · 2019
2/10 SYR4
Mercury
0.5500 µg/L 28%
of the EPA limit 2 µg/L
Highest in the city: ECCO · 100 people · 2019
1/10 SYR4
Lead
0.0029 mg/L 19%
of the EPA limit 0.0150 mg/L
Main supplier: BROADVIEW TERRACE MUTUAL WATER COMPANY · 498 people · 2025
Highest in the city: 0.0146 mg/L — CRASS MUTUAL WATER COMPANY · 80 people · 2020
10/10 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Oakhurst

Frequently asked questions about Oakhurst tap water

Is Oakhurst tap water safe to drink?

EPA testing detected 25 contaminants in the water serving Oakhurst. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Oakhurst?

10 public water suppliers report drinking-water monitoring for Oakhurst, California to the EPA. Each is listed above with its population served.

What contaminants are in Oakhurst's water?

The contaminants EPA monitoring detected in Oakhurst include Nitrate, Nitrate-Nitrite, Fluoride, Nitrite, Combined Uranium. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.