EPA monitoring detected 26 contaminants across the 4 water suppliers serving Pipe Creek. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

4
water suppliers
405
people served
26
contaminants found

What was found in Pipe Creek's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
2560 µg/L 64%
of the EPA limit 4000 µg/L
3/4 SYR4
Nitrate-Nitrite
170 µg/L 1.7%
of the EPA limit 10000 µg/L
2/4 SYR4
Total Haloacetic Acids (HAA5)
142 µg/L 237%
of the EPA limit, in the worst sample — 60 µg/L
1/4 SYR4
Monochloroacetic Acid
140.9 µg/L
No EPA limit set
1/4 SYR4
Nitrate
140 µg/L 1.4%
of the EPA limit 10000 µg/L
3/4 SYR4
Copper
136 µg/L 10%
of the EPA limit 1300 µg/L
3/4 SYR4
Barium
80.7 µg/L 4%
of the EPA limit 2000 µg/L
3/4 SYR4
Nitrite
40 µg/L 4%
of the EPA limit 1000 µg/L
1/4 SYR4
Gross Beta Particle Activity
15.1 pCi/L
No EPA limit set
3/4 SYR4
Gross Alpha, Excl. Radon And U
13 pCi/L 87%
of the EPA limit 15 pCi/L
2/4 SYR4
Cyanide
10 µg/L 5%
of the EPA limit 200 µg/L
1/4 SYR4
Lead
8.25 µg/L 55%
of the EPA limit 15 µg/L
2/4 SYR4
TTHM
8.2 µg/L 10%
of the EPA limit 80 µg/L
2/4 SYR4
Selenium
6.3 µg/L 13%
of the EPA limit 50 µg/L
1/4 SYR4
Trichloroacetic Acid
3.6 µg/L
No EPA limit set
1/4 SYR4
Arsenic
3.4 µg/L 34%
of the EPA limit 10 µg/L
1/4 SYR4
Dibromochloromethane
3 µg/L
No EPA limit set
2/4 SYR4
Bromoform
2.5 µg/L
No EPA limit set
2/4 SYR4
Combined Uranium
2.3 µg/L 7.7%
of the EPA limit 30 µg/L
1/4 SYR4
Bromodichloromethane
1.8 µg/L
No EPA limit set
1/4 SYR4
Dibromoacetic Acid
1.6 µg/L
No EPA limit set
1/4 SYR4
Combined Radium (-226 And -228)
1.56 pCi/L 31%
of the EPA limit 5 pCi/L
3/4 SYR4
Chloroform
1.2 µg/L
No EPA limit set
1/4 SYR4
Dichloroacetic Acid
1.1 µg/L
No EPA limit set
1/4 SYR4
Di(2-ethylhexyl) Phthalate
0.8300 µg/L 14%
of the EPA limit 6 µg/L
1/4 SYR4
Lead
0.0021 mg/L 14%
of the EPA limit 0.0150 mg/L
4/4 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Pipe Creek

Frequently asked questions about Pipe Creek tap water

Is Pipe Creek tap water safe to drink?

EPA testing detected 26 contaminants in the water serving Pipe Creek. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Pipe Creek?

4 public water suppliers report drinking-water monitoring for Pipe Creek, Texas to the EPA. Each is listed above with its population served.

What contaminants are in Pipe Creek's water?

The contaminants EPA monitoring detected in Pipe Creek include Fluoride, Nitrate-Nitrite, Total Haloacetic Acids (HAA5), Monochloroacetic Acid, Nitrate. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.