← Texas

Tap water quality report

Cibolo, TX

EPA monitoring detected 16 contaminants across the 1 water supplier serving Cibolo. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

1
water supplier
20,331
people served
16
contaminants found

What was found in Cibolo's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
492.7 µg/L 38%
of the EPA limit 1300 µg/L
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
TTHM
76.78 µg/L 96%
of the EPA limit 80 µg/L
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Total Haloacetic Acids (HAA5)
42.264999999999965 µg/L 70%
of the EPA limit 60 µg/L
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Lithium
37 µg/L
No EPA limit set
Main supplier: CITY OF CIBOLO · 20,331 people · 2023
1/1 UCMR-5
Dichloroacetic Acid
34.3 µg/L
No EPA limit set
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Dibromochloromethane
22.46 µg/L
No EPA limit set
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Bromodichloromethane
22.239999999999984 µg/L
No EPA limit set
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Chloroform
17.52 µg/L
No EPA limit set
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Bromoform
13.699999999999996 µg/L
No EPA limit set
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Trichloroacetic Acid
13.125 µg/L
No EPA limit set
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Monochloroacetic Acid
8.1 µg/L
No EPA limit set
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Dibromoacetic Acid
7.2199999999999935 µg/L
No EPA limit set
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Lead
7.2039999999999935 µg/L 48%
of the EPA limit 15 µg/L
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Monobromoacetic Acid
5.839999999999999 µg/L
No EPA limit set
Main supplier: CITY OF CIBOLO · 20,331 people · 2019
1/1 SYR4
Pfba
0.0054 µg/L
No EPA limit set
Main supplier: CITY OF CIBOLO · 20,331 people · 2023
1/1 UCMR-5
Lead
0.0011 mg/L 7.3%
of the EPA limit 0.0150 mg/L
Main supplier: CITY OF CIBOLO · 20,331 people · 2025
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Cibolo

SupplierPopulation served
CITY OF CIBOLO 20,331

Frequently asked questions about Cibolo tap water

Is Cibolo tap water safe to drink?

EPA testing detected 16 contaminants in the water serving Cibolo. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Cibolo?

1 public water supplier report drinking-water monitoring for Cibolo, Texas to the EPA. Each is listed above with its population served.

What contaminants are in Cibolo's water?

The contaminants EPA monitoring detected in Cibolo include Copper, TTHM, Total Haloacetic Acids (HAA5), Lithium, Dichloroacetic Acid. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.