← Texas

Tap water quality report

Bridgeport, TX

EPA monitoring detected 30 contaminants across the 3 water suppliers serving Bridgeport. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

3
water suppliers
9,947
people served
30
contaminants found

What was found in Bridgeport's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
1100 µg/L 85%
of the EPA limit 1300 µg/L
3/3 SYR4
TTHM
392 µg/L 490%
of the EPA limit, in the worst sample — 80 µg/L
3/3 SYR4
Total Haloacetic Acids (HAA5)
383 µg/L 638%
of the EPA limit, in the worst sample — 60 µg/L
3/3 SYR4
Nitrate
360 µg/L 3.6%
of the EPA limit 10000 µg/L
2/3 SYR4
Chloroform
345 µg/L
No EPA limit set
3/3 SYR4
Fluoride
250 µg/L 6.3%
of the EPA limit 4000 µg/L
2/3 SYR4
Nitrate-Nitrite
250 µg/L 2.5%
of the EPA limit 10000 µg/L
1/3 SYR4
Trichloroacetic Acid
193 µg/L
No EPA limit set
3/3 SYR4
Cyanide
184 µg/L 92%
of the EPA limit 200 µg/L
2/3 SYR4
Dichloroacetic Acid
163 µg/L
No EPA limit set
3/3 SYR4
Nitrite
152 µg/L 15%
of the EPA limit 1000 µg/L
2/3 SYR4
Barium
119 µg/L 5.9%
of the EPA limit 2000 µg/L
2/3 SYR4
Bromodichloromethane
58.4 µg/L
No EPA limit set
3/3 SYR4
Monochloroacetic Acid
27.5 µg/L
No EPA limit set
3/3 SYR4
Lead
24 µg/L 160%
of the EPA limit, in the worst sample — 15 µg/L
3/3 SYR4
Dibromochloromethane
23 µg/L
No EPA limit set
3/3 SYR4
Dibromoacetic Acid
9.3 µg/L
No EPA limit set
3/3 SYR4
Bromoform
8.7 µg/L
No EPA limit set
3/3 SYR4
Gross Beta Particle Activity
5.4 pCi/L
No EPA limit set
2/3 SYR4
Selenium
3.93 µg/L 7.9%
of the EPA limit 50 µg/L
2/3 SYR4
Chromium
3.3 µg/L 3.3%
of the EPA limit 100 µg/L
2/3 SYR4
Monobromoacetic Acid
3 µg/L
No EPA limit set
3/3 SYR4
Arsenic
2.56 µg/L 26%
of the EPA limit 10 µg/L
2/3 SYR4
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
1/3 SYR4
Di(2-ethylhexyl) Phthalate
0.5000 µg/L 8.3%
of the EPA limit 6 µg/L
1/3 SYR4
Hexachlorocyclopentadiene
0.3700 µg/L 0.7%
of the EPA limit 50 µg/L
1/3 SYR4
Antimony, Total
0.3600 µg/L 6%
of the EPA limit 6 µg/L
1/3 SYR4
Thallium, Total
0.0300 µg/L 1.5%
of the EPA limit 2 µg/L
1/3 SYR4
Pfba
0.0098 µg/L
No EPA limit set
2/3 UCMR-5
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
3/3 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Bridgeport

SupplierPopulation served
CITY OF BRIDGEPORT 5,930
WEST WISE SUD 3,909
HIDEAWAY BAY LAKE SHORES WSC 108

Frequently asked questions about Bridgeport tap water

Is Bridgeport tap water safe to drink?

EPA testing detected 30 contaminants in the water serving Bridgeport. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Bridgeport?

3 public water suppliers report drinking-water monitoring for Bridgeport, Texas to the EPA. Each is listed above with its population served.

What contaminants are in Bridgeport's water?

The contaminants EPA monitoring detected in Bridgeport include Copper, TTHM, Total Haloacetic Acids (HAA5), Nitrate, Chloroform. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.