← Louisiana

Tap water quality report

Campti, LA

EPA monitoring detected 30 contaminants across the 3 water suppliers serving Campti. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

3
water suppliers
2,970
people served
30
contaminants found

What was found in Campti's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
1400 µg/L 108%
of the EPA limit, in the worst sample — 1300 µg/L
3/3 SYR4
Barium
1200 µg/L 60%
of the EPA limit 2000 µg/L
3/3 SYR4
Total Haloacetic Acids (HAA5)
563 µg/L 938%
of the EPA limit, in the worst sample — 60 µg/L
3/3 SYR4
TTHM
414.8 µg/L 519%
of the EPA limit, in the worst sample — 80 µg/L
3/3 SYR4
Chloroform
383 µg/L
No EPA limit set
3/3 SYR4
Nitrate-Nitrite
330 µg/L 3.3%
of the EPA limit 10000 µg/L
3/3 SYR4
Trichloroacetic Acid
316 µg/L
No EPA limit set
3/3 SYR4
Fluoride
280 µg/L 7%
of the EPA limit 4000 µg/L
3/3 SYR4
Dichloroacetic Acid
246 µg/L
No EPA limit set
3/3 SYR4
Lead
110 µg/L 733%
of the EPA limit, in the worst sample — 15 µg/L
3/3 SYR4
Dalapon
91.811 µg/L 46%
of the EPA limit 200 µg/L
1/3 SYR4
Bromodichloromethane
50.9 µg/L
No EPA limit set
3/3 SYR4
Toluene
35.7 µg/L 3.6%
of the EPA limit 1000 µg/L
1/3 SYR4
Monochloroacetic Acid
27.9 µg/L
No EPA limit set
3/3 SYR4
Dibromochloromethane
20 µg/L
No EPA limit set
3/3 SYR4
Gross Beta Particle Activity
8.88 pCi/L
No EPA limit set
3/3 SYR4
Bromoform
8.6 µg/L
No EPA limit set
2/3 SYR4
Gross Alpha, Excl. Radon And U
6.02 pCi/L 40%
of the EPA limit 15 pCi/L
1/3 SYR4
Dibromoacetic Acid
5 µg/L
No EPA limit set
3/3 SYR4
Chromium
4.2 µg/L 4.2%
of the EPA limit 100 µg/L
2/3 SYR4
Monobromoacetic Acid
3.1 µg/L
No EPA limit set
3/3 SYR4
Combined Radium (-226 And -228)
2.4 pCi/L 48%
of the EPA limit 5 pCi/L
3/3 SYR4
Selenium
2.1 µg/L 4.2%
of the EPA limit 50 µg/L
1/3 SYR4
Arsenic
2 µg/L 20%
of the EPA limit 10 µg/L
3/3 SYR4
Xylenes, Total
1.87 µg/L 0%
of the EPA limit 10000 µg/L
1/3 SYR4
Di(2-ethylhexyl) Phthalate
0.8800 µg/L 15%
of the EPA limit 6 µg/L
2/3 SYR4
Carbon Tetrachloride
0.8100 µg/L 16%
of the EPA limit 5 µg/L
1/3 SYR4
Ethylbenzene
0.6100 µg/L 0.1%
of the EPA limit 700 µg/L
1/3 SYR4
Hexachlorocyclopentadiene
0.1610 µg/L 0.3%
of the EPA limit 50 µg/L
1/3 SYR4
Lead
0.0124 mg/L 82%
of the EPA limit 0.0150 mg/L
3/3 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Campti

Frequently asked questions about Campti tap water

Is Campti tap water safe to drink?

EPA testing detected 30 contaminants in the water serving Campti. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Campti?

3 public water suppliers report drinking-water monitoring for Campti, Louisiana to the EPA. Each is listed above with its population served.

What contaminants are in Campti's water?

The contaminants EPA monitoring detected in Campti include Copper, Barium, Total Haloacetic Acids (HAA5), TTHM, Chloroform. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.