← Florida

Tap water quality report

Crescent City, FL

EPA monitoring detected 34 contaminants across the 5 water suppliers serving Crescent City. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

5
water suppliers
3,173
people served
34
contaminants found

What was found in Crescent City's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
1070 µg/L 11%
of the EPA limit 10000 µg/L
4/5 SYR4
Barium
370 µg/L 19%
of the EPA limit 2000 µg/L
5/5 SYR4
TTHM
320 µg/L 400%
of the EPA limit, in the worst sample — 80 µg/L
5/5 SYR4
Total Haloacetic Acids (HAA5)
314.2 µg/L 524%
of the EPA limit, in the worst sample — 60 µg/L
5/5 SYR4
Fluoride
260 µg/L 6.5%
of the EPA limit 4000 µg/L
5/5 SYR4
Carbon Tetrachloride
27 µg/L 540%
of the EPA limit, in the worst sample — 5 µg/L
1/5 SYR4
Arsenic
14 µg/L 140%
of the EPA limit, in the worst sample — 10 µg/L
2/5 SYR4
Chromium
7 µg/L 7%
of the EPA limit 100 µg/L
3/5 SYR4
Copper
5.7 µg/L 0.4%
of the EPA limit 1300 µg/L
5/5 SYR4
Selenium
5.2 µg/L 10%
of the EPA limit 50 µg/L
2/5 SYR4
Xylenes, Total
4.6 µg/L 0%
of the EPA limit 10000 µg/L
3/5 SYR4
Dalapon
2.6 µg/L 1.3%
of the EPA limit 200 µg/L
3/5 SYR4
1,2,4-Trichlorobenzene
1.6 µg/L 2.3%
of the EPA limit 70 µg/L
1/5 SYR4
Ethylbenzene
1.1 µg/L 0.2%
of the EPA limit 700 µg/L
3/5 SYR4
Cyanide
1 µg/L 0.5%
of the EPA limit 200 µg/L
1/5 SYR4
O-Dichlorobenzene
0.4600 µg/L 0.1%
of the EPA limit 600 µg/L
1/5 SYR4
Dichloromethane
0.4400 µg/L 8.8%
of the EPA limit 5 µg/L
1/5 SYR4
1,1,1-Trichloroethane
0.3900 µg/L 0.2%
of the EPA limit 200 µg/L
1/5 SYR4
Styrene
0.3900 µg/L 0.4%
of the EPA limit 100 µg/L
1/5 SYR4
1,2-Dichloroethane
0.3600 µg/L 7.2%
of the EPA limit 5 µg/L
1/5 SYR4
cis-1,2-Dichloroethylene
0.3200 µg/L 0.5%
of the EPA limit 70 µg/L
1/5 SYR4
Trichloroethylene
0.2800 µg/L 5.6%
of the EPA limit 5 µg/L
1/5 SYR4
1,2-Dichloropropane
0.2600 µg/L 5.2%
of the EPA limit 5 µg/L
1/5 SYR4
P-Dichlorobenzene
0.2600 µg/L 0.3%
of the EPA limit 75 µg/L
1/5 SYR4
trans-1,2-Dichloroethylene
0.2600 µg/L 0.3%
of the EPA limit 100 µg/L
1/5 SYR4
Tetrachloroethylene
0.2400 µg/L 4.8%
of the EPA limit 5 µg/L
1/5 SYR4
Toluene
0.2200 µg/L 0%
of the EPA limit 1000 µg/L
1/5 SYR4
Beryllium, Total
0.2000 µg/L 5%
of the EPA limit 4 µg/L
1/5 SYR4
Vinyl Chloride
0.2000 µg/L 10%
of the EPA limit 2 µg/L
1/5 SYR4
1,1-Dichloroethylene
0.1800 µg/L 2.6%
of the EPA limit 7 µg/L
1/5 SYR4
Benzene
0.1700 µg/L 3.4%
of the EPA limit 5 µg/L
1/5 SYR4
1,1,2-Trichloroethane
0.1200 µg/L 2.4%
of the EPA limit 5 µg/L
1/5 SYR4
Chlorobenzene
0.1200 µg/L 0.1%
of the EPA limit 100 µg/L
1/5 SYR4
Lead
0.0050 mg/L 33%
of the EPA limit 0.0150 mg/L
5/5 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Crescent City

Frequently asked questions about Crescent City tap water

Is Crescent City tap water safe to drink?

EPA testing detected 34 contaminants in the water serving Crescent City. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Crescent City?

5 public water suppliers report drinking-water monitoring for Crescent City, Florida to the EPA. Each is listed above with its population served.

What contaminants are in Crescent City's water?

The contaminants EPA monitoring detected in Crescent City include Nitrate, Barium, TTHM, Total Haloacetic Acids (HAA5), Fluoride. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.