What was found in Alhambra's water
The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.
| Contaminant | Level vs EPA limit | Suppliers | Source |
|---|---|---|---|
| Nitrate | 15142 µg/L 151% of the EPA limit, in the worst sample — 10000 µg/L | 8/10 | SYR4 |
| Nitrate-Nitrite | 13000 µg/L 130% of the EPA limit, in the worst sample — 10000 µg/L | 8/10 | SYR4 |
| Fluoride | 2840 µg/L 71% of the EPA limit 4000 µg/L | 8/10 | SYR4 |
| Barium | 196 µg/L 9.8% of the EPA limit 2000 µg/L | 4/10 | SYR4 |
| TTHM | 151 µg/L 189% of the EPA limit, in the worst sample — 80 µg/L | 10/10 | SYR4 |
| Arsenic | 78.5 µg/L 785% of the EPA limit, in the worst sample — 10 µg/L | 3/10 | SYR4 |
| Bromoform | 58.7 µg/L No EPA limit set | 10/10 | SYR4 |
| Lithium | 58 µg/L No EPA limit set | 3/10 | UCMR-5 |
| Dibromochloromethane | 54 µg/L No EPA limit set | 10/10 | SYR4 |
| cis-1,2-Dichloroethylene | 50 µg/L 71% of the EPA limit 70 µg/L | 1/10 | SYR4 |
| Total Haloacetic Acids (HAA5) | 45 µg/L 75% of the EPA limit 60 µg/L | 10/10 | SYR4 |
| Bromodichloromethane | 37.8 µg/L No EPA limit set | 10/10 | SYR4 |
| Chromium | 35.9 µg/L 36% of the EPA limit 100 µg/L | 5/10 | SYR4 |
| Trichloroethylene | 31 µg/L 620% of the EPA limit, in the worst sample — 5 µg/L | 1/10 | SYR4 |
| Chloroform | 29.2 µg/L No EPA limit set | 10/10 | SYR4 |
| Trichloroacetic Acid | 28 µg/L No EPA limit set | 9/10 | SYR4 |
| Dibromoacetic Acid | 19.2 µg/L No EPA limit set | 10/10 | SYR4 |
| Dichloroacetic Acid | 17 µg/L No EPA limit set | 9/10 | SYR4 |
| Selenium | 12.1 µg/L 24% of the EPA limit 50 µg/L | 2/10 | SYR4 |
| Combined Uranium | 11.771 µg/L 39% of the EPA limit 30 µg/L | 6/10 | SYR4 |
| Di(2-ethylhexyl) Phthalate | 11 µg/L 183% of the EPA limit, in the worst sample — 6 µg/L | 1/10 | SYR4 |
| Lead | 6.2 µg/L 41% of the EPA limit 15 µg/L | 1/10 | SYR4 |
| Tetrachloroethylene | 4.7 µg/L 94% of the EPA limit 5 µg/L | 1/10 | SYR4 |
| Gross Beta Particle Activity | 4.14 pCi/L No EPA limit set | 1/10 | SYR4 |
| Monobromoacetic Acid | 3.88 µg/L No EPA limit set | 7/10 | SYR4 |
| Combined Radium (-226 And -228) | 2.9 pCi/L 58% of the EPA limit 5 pCi/L | 1/10 | SYR4 |
| trans-1,2-Dichloroethylene | 0.8300 µg/L 0.8% of the EPA limit 100 µg/L | 1/10 | SYR4 |
| 1,1-Dichloroethylene | 0.7700 µg/L 11% of the EPA limit 7 µg/L | 1/10 | SYR4 |
| Toluene | 0.5710 µg/L 0.1% of the EPA limit 1000 µg/L | 1/10 | SYR4 |
| Carbon Tetrachloride | 0.5200 µg/L 10% of the EPA limit 5 µg/L | 1/10 | SYR4 |
| 1,2-DIBROMO-3-CHLOROPROPANE | 0.1300 µg/L 65% of the EPA limit 0.2000 µg/L | 1/10 | SYR4 |
| Lead | 0.0558 mg/L 372% above the EPA limit of 0.0150 mg/L | 10/10 | LCR |
Water suppliers serving Alhambra
| Supplier | Population served |
|---|---|
| LOS ANGELES CWWD 40 REG 4 & 34 LANCASTER | 208,129 |
| CITY OF ALHAMBRA | 79,776 |
| LOS ANGELES CWWD 29 & 80-MALIBU | 32,348 |
| LOS ANGELES CWWD 40, REG. 38-LAKE LA | 12,568 |
| LOS ANGELES CWWD 40, R 24,27,33-PEARBLSM | 11,509 |
| LOS ANGELES CWWD 36-VAL VERDE | 6,376 |
| LOS ANGELES CWWD 37-ACTON | 4,805 |
| LOS ANGELES CWWD 40, REG. 39-ROCK CREEK | 994 |
| LOS ANGELES CWWD 21-KAGEL CANYON | 708 |
| LOS ANGELES CWWD 40, REG. 35-N.E. L.A. | 612 |
Frequently asked questions about Alhambra tap water
Is Alhambra tap water safe to drink?
EPA testing detected 32 contaminants in the water serving Alhambra. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.
How many water suppliers serve Alhambra?
10 public water suppliers report drinking-water monitoring for Alhambra, California to the EPA. Each is listed above with its population served.
What contaminants are in Alhambra's water?
The contaminants EPA monitoring detected in Alhambra include Nitrate, Nitrate-Nitrite, Fluoride, Barium, TTHM. The full list, with the highest level found and the data source, is in the table above.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.