EPA monitoring across the 3 water suppliers serving ZIP 84098 in Park City, UT detected 29 contaminants. A detection doesn't automatically mean the water is unsafe — see the highest level found below, with the EPA limit for each.

3
water suppliers
18,550
people served
29
contaminants found

What was found in ZIP 84098

The highest level seen across the suppliers serving this ZIP, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
1400 µg/L 14%
of the EPA limit 10000 µg/L
2/3 SYR4
Nitrate-Nitrite
1100 µg/L 11%
of the EPA limit 10000 µg/L
2/3 SYR4
Copper
1060 µg/L 82%
of the EPA limit 1300 µg/L
3/3 SYR4
Fluoride
500 µg/L 13%
of the EPA limit 4000 µg/L
2/3 SYR4
Barium
354.9 µg/L 18%
of the EPA limit 2000 µg/L
2/3 SYR4
Lithium
84 µg/L
No EPA limit set
3/3 UCMR-5
TTHM
38.8 µg/L 49%
of the EPA limit 80 µg/L
3/3 SYR4
Lead
27.3 µg/L 182%
of the EPA limit, in the worst sample — 15 µg/L
3/3 SYR4
Chloroform
26.8 µg/L
No EPA limit set
2/3 SYR4
Total Haloacetic Acids (HAA5)
26.3 µg/L 44%
of the EPA limit 60 µg/L
3/3 SYR4
Cyanide
24 µg/L 12%
of the EPA limit 200 µg/L
2/3 SYR4
Dichloroacetic Acid
13.4 µg/L
No EPA limit set
2/3 SYR4
Trichloroacetic Acid
12.9 µg/L
No EPA limit set
2/3 SYR4
Selenium
10.2 µg/L 20%
of the EPA limit 50 µg/L
2/3 SYR4
Gross Beta Particle Activity
9 pCi/L
No EPA limit set
2/3 SYR4
Bromodichloromethane
8.4 µg/L
No EPA limit set
3/3 SYR4
Gross Alpha, Excl. Radon And U
8.3 pCi/L 55%
of the EPA limit 15 pCi/L
2/3 SYR4
Dibromochloromethane
7.8 µg/L
No EPA limit set
3/3 SYR4
Arsenic
3.4 µg/L 34%
of the EPA limit 10 µg/L
2/3 SYR4
Bromoform
3.3 µg/L
No EPA limit set
3/3 SYR4
Dibromoacetic Acid
2.7 µg/L
No EPA limit set
3/3 SYR4
Combined Radium (-226 And -228)
1.17 pCi/L 23%
of the EPA limit 5 pCi/L
2/3 SYR4
Antimony, Total
0.5000 µg/L 8.3%
of the EPA limit 6 µg/L
1/3 SYR4
Trichloroethylene
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/3 SYR4
Thallium, Total
0.2000 µg/L 10%
of the EPA limit 2 µg/L
1/3 SYR4
6:2 Fts
0.0550 µg/L
No EPA limit set
1/3 UCMR-5
Pfpea
0.0140 µg/L
No EPA limit set
1/3 UCMR-5
Lead
0.0082 mg/L 55%
of the EPA limit 0.0150 mg/L
3/3 LCR
Pfhxa
0.0081 µg/L
No EPA limit set
1/3 UCMR-5
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 84098

SupplierStatePopulation served
MOUNTAIN REGIONAL WATER SSD UT 8,245
SUMMIT WATER DISTRIBUTION COMPANY UT 6,000
GORGOZA MUTUAL WATER CO UT 4,305

Frequently asked questions about ZIP 84098 tap water

Is the tap water in ZIP 84098 safe to drink?

EPA testing detected 29 contaminants across the water suppliers serving ZIP 84098. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 84098?

3 public water suppliers report EPA drinking-water monitoring for ZIP 84098. Each is listed above with its population served.

What contaminants are in ZIP 84098's water?

EPA monitoring detected Nitrate, Nitrate-Nitrite, Copper, Fluoride, Barium, and others across this ZIP's suppliers. The full list with levels and sources is above.