EPA monitoring across the 2 water suppliers serving ZIP 64761 in Holden, MO detected 17 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

2
water suppliers
17,190
people served
17
contaminants found

What was found in ZIP 64761

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
418.5 µg/L 10%
of the EPA limit 4000 µg/L
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2017
Highest in the ZIP: 680 µg/L — JOHNSON COUNTY PWSD 3 · 4,700 people · 2017
2/2 SYR4
Copper
249 µg/L 19%
of the EPA limit 1300 µg/L
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
Highest in the ZIP: 531.0999999999992 µg/L — JOHNSON COUNTY PWSD 3 · 4,700 people · 2018
2/2 SYR4
Barium
105.95 µg/L 5.3%
of the EPA limit 2000 µg/L
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2017
Highest in the ZIP: 122.4 µg/L — JOHNSON COUNTY PWSD 3 · 4,700 people · 2017
2/2 SYR4
Lithium
29.6 µg/L
No EPA limit set
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2024
2/2 UCMR-5
Lead
20.49 µg/L 137%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
2/2 SYR4
Nitrate-Nitrite
16 µg/L 0.2%
of the EPA limit 10000 µg/L
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
2/2 SYR4
TTHM
6.176 µg/L 7.7%
of the EPA limit 80 µg/L
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
1/2 SYR4
Dibromochloromethane
2.3345 µg/L
No EPA limit set
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
2/2 SYR4
Chromium
2.09 µg/L 2.1%
of the EPA limit 100 µg/L
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2017
Highest in the ZIP: 2.2585 µg/L — JOHNSON COUNTY PWSD 3 · 4,700 people · 2017
2/2 SYR4
Combined Radium (-226 And -228)
1.5950000000000002 pCi/L 32%
of the EPA limit 5 pCi/L
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2018
Highest in the ZIP: 1.8849999999999998 pCi/L — JOHNSON COUNTY PWSD 3 · 4,700 people · 2019
2/2 SYR4
Xylenes, Total
1.79 µg/L 0%
of the EPA limit 10000 µg/L
Highest in the ZIP: JOHNSON COUNTY PWSD 3 · 4,700 people · 2017
1/2 SYR4
Bromodichloromethane
1.612 µg/L
No EPA limit set
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
2/2 SYR4
Dichloroacetic Acid
1.494 µg/L
No EPA limit set
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
1/2 SYR4
Bromoform
1.458 µg/L
No EPA limit set
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
2/2 SYR4
Chloroform
0.8555 µg/L
No EPA limit set
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
1/2 SYR4
Ethylbenzene
0.5900 µg/L 0.1%
of the EPA limit 700 µg/L
Highest in the ZIP: JOHNSON COUNTY PWSD 3 · 4,700 people · 2017
1/2 SYR4
Lead
0.0019 mg/L 12%
of the EPA limit 0.0150 mg/L
Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2024
2/2 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 64761

SupplierStatePopulation served
JOHNSON COUNTY PWSD 2 MO 12,490
JOHNSON COUNTY PWSD 3 MO 4,700

Frequently asked questions about ZIP 64761 tap water

Is the tap water in ZIP 64761 safe to drink?

EPA testing detected 17 contaminants across the water suppliers serving ZIP 64761. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 64761?

2 public water suppliers report EPA drinking-water monitoring for ZIP 64761. Each is listed above with its population served.

What contaminants are in ZIP 64761's water?

EPA monitoring detected Fluoride, Copper, Barium, Lithium, Lead, and others across this ZIP's suppliers. The full list with levels and sources is above.