What was found in ZIP 64019
The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.
| Contaminant | Level vs EPA limit | Suppliers | Source |
|---|---|---|---|
| Copper | 249 µg/L 19% of the EPA limit 1300 µg/L Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
Highest in the ZIP: 1120 µg/L — JOHNSON COUNTY PWSD 1 · 3,730 people · 2018 | 2/2 | SYR4 |
| Fluoride | 418.5 µg/L 10% of the EPA limit 4000 µg/L Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2017
Highest in the ZIP: 770 µg/L — JOHNSON COUNTY PWSD 1 · 3,730 people · 2016 | 2/2 | SYR4 |
| Lithium | 29.6 µg/L No EPA limit set Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2024
Highest in the ZIP: 130 µg/L — JOHNSON COUNTY PWSD 1 · 3,730 people · 2024 | 2/2 | UCMR-5 |
| Barium | 105.95 µg/L 5.3% of the EPA limit 2000 µg/L Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2017 | 2/2 | SYR4 |
| TTHM | 6.176 µg/L 7.7% of the EPA limit 80 µg/L Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
Highest in the ZIP: 37.925 µg/L — JOHNSON COUNTY PWSD 1 · 3,730 people · 2019 | 2/2 | SYR4 |
| Lead | 20.49 µg/L 137% of the EPA limit, at the 95th percentile of samples — 15 µg/L Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019 | 2/2 | SYR4 |
| Nitrate-Nitrite | 16 µg/L 0.2% of the EPA limit 10000 µg/L Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019 | 1/2 | SYR4 |
| Bromodichloromethane | 1.612 µg/L No EPA limit set Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
Highest in the ZIP: 14.90999999999999 µg/L — JOHNSON COUNTY PWSD 1 · 3,730 people · 2019 | 2/2 | SYR4 |
| Dibromochloromethane | 2.3345 µg/L No EPA limit set Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
Highest in the ZIP: 13.909999999999993 µg/L — JOHNSON COUNTY PWSD 1 · 3,730 people · 2019 | 2/2 | SYR4 |
| Bromoform | 1.458 µg/L No EPA limit set Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
Highest in the ZIP: 5.1739999999999995 µg/L — JOHNSON COUNTY PWSD 1 · 3,730 people · 2019 | 2/2 | SYR4 |
| Dichloroacetic Acid | 1.494 µg/L No EPA limit set Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
Highest in the ZIP: 5.0305 µg/L — JOHNSON COUNTY PWSD 1 · 3,730 people · 2019 | 2/2 | SYR4 |
| Chloroform | 0.8555 µg/L No EPA limit set Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2019
Highest in the ZIP: 2.586 µg/L — JOHNSON COUNTY PWSD 1 · 3,730 people · 2019 | 2/2 | SYR4 |
| Chromium | 2.09 µg/L 2.1% of the EPA limit 100 µg/L Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2017 | 1/2 | SYR4 |
| Dibromoacetic Acid | 1.689 µg/L No EPA limit set Highest in the ZIP: JOHNSON COUNTY PWSD 1 · 3,730 people · 2019 | 1/2 | SYR4 |
| Combined Radium (-226 And -228) | 1.5950000000000002 pCi/L 32% of the EPA limit 5 pCi/L Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2018 | 1/2 | SYR4 |
| Lead | 0.0019 mg/L 12% of the EPA limit 0.0150 mg/L Main supplier: JOHNSON COUNTY PWSD 2 · 12,490 people · 2024 | 2/2 | LCR |
Water suppliers serving ZIP 64019
| Supplier | State | Population served |
|---|---|---|
| JOHNSON COUNTY PWSD 2 | MO | 12,490 |
| JOHNSON COUNTY PWSD 1 | MO | 3,730 |
Frequently asked questions about ZIP 64019 tap water
Is the tap water in ZIP 64019 safe to drink?
EPA testing detected 16 contaminants across the water suppliers serving ZIP 64019. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.
Which water suppliers serve ZIP 64019?
2 public water suppliers report EPA drinking-water monitoring for ZIP 64019. Each is listed above with its population served.
What contaminants are in ZIP 64019's water?
EPA monitoring detected Copper, Fluoride, Lithium, Barium, TTHM, and others across this ZIP's suppliers. The full list with levels and sources is above.