← Rockford, IL

Tap water quality report

ZIP 61101 — Rockford, IL

EPA monitoring across the 1 water supplier serving ZIP 61101 in Rockford, IL detected 29 contaminants. A detection doesn't automatically mean the water is unsafe — see the highest level found below, with the EPA limit for each.

1
water supplier
147,051
people served
29
contaminants found

What was found in ZIP 61101

The highest level seen across the suppliers serving this ZIP, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
4400 µg/L 44%
of the EPA limit 10000 µg/L
1/1 SYR4
Nitrate-Nitrite
4300 µg/L 43%
of the EPA limit 10000 µg/L
1/1 SYR4
Copper
3400 µg/L 262%
of the EPA limit, in the worst sample — 1300 µg/L
1/1 SYR4
Fluoride
1460 µg/L 37%
of the EPA limit 4000 µg/L
1/1 SYR4
Barium
920 µg/L 46%
of the EPA limit 2000 µg/L
1/1 SYR4
Lead
110 µg/L 733%
of the EPA limit, in the worst sample — 15 µg/L
1/1 SYR4
Total Haloacetic Acids (HAA5)
90.2 µg/L 150%
of the EPA limit, in the worst sample — 60 µg/L
1/1 SYR4
Monobromoacetic Acid
81.5 µg/L
No EPA limit set
1/1 SYR4
TTHM
42 µg/L 53%
of the EPA limit 80 µg/L
1/1 SYR4
Chloroform
34 µg/L
No EPA limit set
1/1 SYR4
Dichloroacetic Acid
15 µg/L
No EPA limit set
1/1 SYR4
cis-1,2-Dichloroethylene
13 µg/L 19%
of the EPA limit 70 µg/L
1/1 SYR4
1,1,1-Trichloroethane
9.5 µg/L 4.8%
of the EPA limit 200 µg/L
1/1 SYR4
Trichloroacetic Acid
9 µg/L
No EPA limit set
1/1 SYR4
Arsenic
8.9 µg/L 89%
of the EPA limit 10 µg/L
1/1 SYR4
Bromodichloromethane
6.3 µg/L
No EPA limit set
1/1 SYR4
Combined Radium (-226 And -228)
6 pCi/L 120%
of the EPA limit, in the worst sample — 5 pCi/L
1/1 SYR4
Chromium
5.9 µg/L 5.9%
of the EPA limit 100 µg/L
1/1 SYR4
Dibromochloromethane
3.5 µg/L
No EPA limit set
1/1 SYR4
Selenium
2.8 µg/L 5.6%
of the EPA limit 50 µg/L
1/1 SYR4
Tetrachloroethylene
2.4 µg/L 48%
of the EPA limit 5 µg/L
1/1 SYR4
Trichloroethylene
2.2 µg/L 44%
of the EPA limit 5 µg/L
1/1 SYR4
Bromoform
2.1 µg/L
No EPA limit set
1/1 SYR4
Dibromoacetic Acid
1.4 µg/L
No EPA limit set
1/1 SYR4
trans-1,2-Dichloroethylene
1.3 µg/L 1.3%
of the EPA limit 100 µg/L
1/1 SYR4
Carbon Tetrachloride
0.8600 µg/L 17%
of the EPA limit 5 µg/L
1/1 SYR4
Lead
0.0073 mg/L 49%
of the EPA limit 0.0150 mg/L
1/1 LCR
PFHXS
0.0066 µg/L
No EPA limit set
1/1 UCMR-5
Pfpea
0.0044 µg/L
No EPA limit set
1/1 UCMR-5
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 61101

SupplierStatePopulation served
ROCKFORD IL 147,051

Frequently asked questions about ZIP 61101 tap water

Is the tap water in ZIP 61101 safe to drink?

EPA testing detected 29 contaminants across the water suppliers serving ZIP 61101. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 61101?

1 public water supplier report EPA drinking-water monitoring for ZIP 61101. Each is listed above with its population served.

What contaminants are in ZIP 61101's water?

EPA monitoring detected Nitrate, Nitrate-Nitrite, Copper, Fluoride, Barium, and others across this ZIP's suppliers. The full list with levels and sources is above.