← Carpentersville, IL

Tap water quality report

ZIP 60118 — Carpentersville, IL

EPA monitoring across the 3 water suppliers serving ZIP 60118 in Carpentersville, IL detected 23 contaminants. A detection doesn't automatically mean the water is unsafe — see the highest level found below, with the EPA limit for each.

3
water suppliers
49,755
people served
23
contaminants found

What was found in ZIP 60118

The highest level seen across the suppliers serving this ZIP, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Barium
16000 µg/L 800%
of the EPA limit, in the worst sample — 2000 µg/L
2/3 SYR4
Fluoride
1230 µg/L 31%
of the EPA limit 4000 µg/L
2/3 SYR4
Copper
1120 µg/L 86%
of the EPA limit 1300 µg/L
3/3 SYR4
Nitrate
490 µg/L 4.9%
of the EPA limit 10000 µg/L
1/3 SYR4
TTHM
72.1 µg/L 90%
of the EPA limit 80 µg/L
3/3 SYR4
Total Haloacetic Acids (HAA5)
63.9 µg/L 107%
of the EPA limit, in the worst sample — 60 µg/L
3/3 SYR4
Chloroform
57.6 µg/L
No EPA limit set
3/3 SYR4
Dichloroacetic Acid
36.6 µg/L
No EPA limit set
3/3 SYR4
Trichloroacetic Acid
32.5 µg/L
No EPA limit set
3/3 SYR4
Lead
30.1 µg/L 201%
of the EPA limit, in the worst sample — 15 µg/L
3/3 SYR4
Combined Radium (-226 And -228)
18.7 pCi/L 374%
of the EPA limit, in the worst sample — 5 pCi/L
2/3 SYR4
Bromodichloromethane
14 µg/L
No EPA limit set
3/3 SYR4
Dibromochloromethane
12.2 µg/L
No EPA limit set
3/3 SYR4
Lithium
10.7 µg/L
No EPA limit set
1/3 UCMR-5
Monochloroacetic Acid
5.87 µg/L
No EPA limit set
2/3 SYR4
Bromoform
4.83 µg/L
No EPA limit set
2/3 SYR4
Dibromoacetic Acid
3.3 µg/L
No EPA limit set
3/3 SYR4
Monobromoacetic Acid
3.17 µg/L
No EPA limit set
1/3 SYR4
Arsenic
1.5 µg/L 15%
of the EPA limit 10 µg/L
1/3 SYR4
Dalapon
0.9980 µg/L 0.5%
of the EPA limit 200 µg/L
1/3 SYR4
Mercury
0.1400 µg/L 7%
of the EPA limit 2 µg/L
1/3 SYR4
Lead
0.0080 mg/L 53%
of the EPA limit 0.0150 mg/L
3/3 LCR
Pfba
0.0056 µg/L
No EPA limit set
1/3 UCMR-5
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 60118

SupplierStatePopulation served
CARPENTERSVILLE IL 37,983
WEST DUNDEE IL 7,845
CORINTH PWD IL 3,927

Frequently asked questions about ZIP 60118 tap water

Is the tap water in ZIP 60118 safe to drink?

EPA testing detected 23 contaminants across the water suppliers serving ZIP 60118. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 60118?

3 public water suppliers report EPA drinking-water monitoring for ZIP 60118. Each is listed above with its population served.

What contaminants are in ZIP 60118's water?

EPA monitoring detected Barium, Fluoride, Copper, Nitrate, TTHM, and others across this ZIP's suppliers. The full list with levels and sources is above.