← Manning, IA

Tap water quality report

ZIP 51454 — Manning, IA

EPA monitoring across the 1 water supplier serving ZIP 51454 in Manning, IA detected 16 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

1
water supplier
3,573
people served
16
contaminants found

What was found in ZIP 51454

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
6300 µg/L 63%
of the EPA limit 10000 µg/L
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2019
1/1 SYR4
Copper
922 µg/L 71%
of the EPA limit 1300 µg/L
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2017
1/1 SYR4
Fluoride
805 µg/L 20%
of the EPA limit 4000 µg/L
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2015
1/1 SYR4
Barium
120 µg/L 6%
of the EPA limit 2000 µg/L
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2012
1/1 SYR4
TTHM
46.199999999999996 µg/L 58%
of the EPA limit 80 µg/L
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2018
1/1 SYR4
Lithium
17 µg/L
No EPA limit set
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2025
1/1 UCMR-5
Bromodichloromethane
14.399999999999999 µg/L
No EPA limit set
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2018
1/1 SYR4
Dibromochloromethane
13.799999999999997 µg/L
No EPA limit set
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2018
1/1 SYR4
Chloroform
12.399999999999999 µg/L
No EPA limit set
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2018
1/1 SYR4
Total Haloacetic Acids (HAA5)
9 µg/L 15%
of the EPA limit 60 µg/L
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2018
1/1 SYR4
Lead
6.399999999999999 µg/L 43%
of the EPA limit 15 µg/L
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2017
1/1 SYR4
Bromoform
5.859999999999998 µg/L
No EPA limit set
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2018
1/1 SYR4
Dichloroacetic Acid
5 µg/L
No EPA limit set
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2018
1/1 SYR4
Dibromoacetic Acid
4 µg/L
No EPA limit set
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2018
1/1 SYR4
Trichloroacetic Acid
2.6499999999999995 µg/L
No EPA limit set
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2018
1/1 SYR4
Lead
0.0017 mg/L 11%
of the EPA limit 0.0150 mg/L
Main supplier: WEST CENTRAL RWA - NISH SYSTEM · 3,573 people · 2023
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 51454

SupplierStatePopulation served
WEST CENTRAL RWA - NISH SYSTEM IA 3,573

Frequently asked questions about ZIP 51454 tap water

Is the tap water in ZIP 51454 safe to drink?

EPA testing detected 16 contaminants across the water suppliers serving ZIP 51454. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 51454?

1 public water supplier report EPA drinking-water monitoring for ZIP 51454. Each is listed above with its population served.

What contaminants are in ZIP 51454's water?

EPA monitoring detected Nitrate, Copper, Fluoride, Barium, TTHM, and others across this ZIP's suppliers. The full list with levels and sources is above.