What was found in ZIP 41033
The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.
| Contaminant | Level vs EPA limit | Suppliers | Source |
|---|---|---|---|
| Fluoride | 1100 µg/L 28% of the EPA limit 4000 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019 | 1/2 | SYR4 |
| Nitrate | 997.5 µg/L 10% of the EPA limit 10000 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019 | 1/2 | SYR4 |
| Copper | 390.3 µg/L 30% of the EPA limit 1300 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019
Highest in the ZIP: 592 µg/L — PENDLETON CO WATER DISTRICT #1/SOUTH · 3,713 people · 2018 | 2/2 | SYR4 |
| TTHM | 96.66 µg/L 121% of the EPA limit, at the 95th percentile of samples — 80 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019
Highest in the ZIP: 116.5 µg/L — PENDLETON CO WATER DISTRICT #1/SOUTH · 3,713 people · 2019 | 2/2 | SYR4 |
| Total Haloacetic Acids (HAA5) | 73.3 µg/L 122% of the EPA limit, at the 95th percentile of samples — 60 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019 | 2/2 | SYR4 |
| Lead | 47.595 µg/L 317% of the EPA limit, at the 95th percentile of samples — 15 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019 | 2/2 | SYR4 |
| Barium | 13 µg/L 0.7% of the EPA limit 2000 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019 | 1/2 | SYR4 |
| Arsenic | 3.18 µg/L 32% of the EPA limit 10 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019 | 1/2 | SYR4 |
| Combined Radium (-226 And -228) | 1.5 pCi/L 30% of the EPA limit 5 pCi/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2014 | 1/2 | SYR4 |
| 1,2-Dichloroethane | 1.2 µg/L 24% of the EPA limit 5 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019 | 1/2 | SYR4 |
| Xylenes, Total | 0.9000 µg/L 0% of the EPA limit 10000 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019 | 1/2 | SYR4 |
| Chlorobenzene | 0.8700 µg/L 0.9% of the EPA limit 100 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019 | 1/2 | SYR4 |
| Mercury | 0.4000 µg/L 20% of the EPA limit 2 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019 | 1/2 | SYR4 |
| Chromium | 0.3000 µg/L 0.3% of the EPA limit 100 µg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2019 | 1/2 | SYR4 |
| Pfpea | 0.0040 µg/L No EPA limit set Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2025
Highest in the ZIP: 0.0160 µg/L — PENDLETON CO WATER DISTRICT #1/SOUTH · 3,713 people · 2023 | 2/2 | UCMR-5 |
| Pfhpa | 0.0130 µg/L No EPA limit set Highest in the ZIP: PENDLETON CO WATER DISTRICT #1/SOUTH · 3,713 people · 2023 | 1/2 | UCMR-5 |
| Pfhxa | 0.0092 µg/L No EPA limit set Highest in the ZIP: PENDLETON CO WATER DISTRICT #1/SOUTH · 3,713 people · 2023 | 1/2 | UCMR-5 |
| Pfba | 0.0072 µg/L No EPA limit set Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2025
Highest in the ZIP: 0.0082 µg/L — PENDLETON CO WATER DISTRICT #1/SOUTH · 3,713 people · 2023 | 2/2 | UCMR-5 |
| Lead | 0.00030 mg/L 2% of the EPA limit 0.0150 mg/L Main supplier: BULLOCK PEN WATER DISTRICT · 20,048 people · 2025
Highest in the ZIP: 0.0047 mg/L — PENDLETON CO WATER DISTRICT #1/SOUTH · 3,713 people · 2024 | 2/2 | LCR |
Water suppliers serving ZIP 41033
| Supplier | State | Population served |
|---|---|---|
| BULLOCK PEN WATER DISTRICT | KY | 20,048 |
| PENDLETON CO WATER DISTRICT #1/SOUTH | KY | 3,713 |
Frequently asked questions about ZIP 41033 tap water
Is the tap water in ZIP 41033 safe to drink?
EPA testing detected 19 contaminants across the water suppliers serving ZIP 41033. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.
Which water suppliers serve ZIP 41033?
2 public water suppliers report EPA drinking-water monitoring for ZIP 41033. Each is listed above with its population served.
What contaminants are in ZIP 41033's water?
EPA monitoring detected Fluoride, Nitrate, Copper, TTHM, Total Haloacetic Acids (HAA5), and others across this ZIP's suppliers. The full list with levels and sources is above.