← Hobe Sound, FL

Tap water quality report

ZIP 33455 — Hobe Sound, FL

EPA monitoring across the 1 water supplier serving ZIP 33455 in Hobe Sound, FL detected 13 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

1
water supplier
27,000
people served
13
contaminants found

What was found in ZIP 33455

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
1390.5 µg/L 14%
of the EPA limit 10000 µg/L
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2019
1/1 SYR4
Nitrite
149.75 µg/L 15%
of the EPA limit 1000 µg/L
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2019
1/1 SYR4
Total Haloacetic Acids (HAA5)
56.435 µg/L 94%
of the EPA limit 60 µg/L
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2019
1/1 SYR4
TTHM
28.045 µg/L 35%
of the EPA limit 80 µg/L
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2019
1/1 SYR4
Barium
5.7 µg/L 0.3%
of the EPA limit 2000 µg/L
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2017
1/1 SYR4
Chromium
1.585 µg/L 1.6%
of the EPA limit 100 µg/L
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2017
1/1 SYR4
PFOS
0.0130 µg/L
No EPA limit set
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2024
1/1 UCMR-5
PFOA
0.0080 µg/L
No EPA limit set
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2024
1/1 UCMR-5
PFBS
0.0046 µg/L
No EPA limit set
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2024
1/1 UCMR-5
PFHXS
0.0044 µg/L
No EPA limit set
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2024
1/1 UCMR-5
Pfpea
0.0044 µg/L
No EPA limit set
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2024
1/1 UCMR-5
Pfhxa
0.0037 µg/L
No EPA limit set
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2024
1/1 UCMR-5
Lead
0.0011 mg/L 7.3%
of the EPA limit 0.0150 mg/L
Main supplier: SOUTH MARTIN REGIONAL UTILITIES · 27,000 people · 2023
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 33455

SupplierStatePopulation served
SOUTH MARTIN REGIONAL UTILITIES FL 27,000

Frequently asked questions about ZIP 33455 tap water

Is the tap water in ZIP 33455 safe to drink?

EPA testing detected 13 contaminants across the water suppliers serving ZIP 33455. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 33455?

1 public water supplier report EPA drinking-water monitoring for ZIP 33455. Each is listed above with its population served.

What contaminants are in ZIP 33455's water?

EPA monitoring detected Nitrate, Nitrite, Total Haloacetic Acids (HAA5), TTHM, Barium, and others across this ZIP's suppliers. The full list with levels and sources is above.