← Snow Hill, NC

Tap water quality report

ZIP 28554 — Snow Hill, NC

EPA monitoring across the 1 water supplier serving ZIP 28554 in Snow Hill, NC detected 16 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

1
water supplier
11,026
people served
16
contaminants found

What was found in ZIP 28554

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
620 µg/L 16%
of the EPA limit 4000 µg/L
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2019
1/1 SYR4
Copper
520.8 µg/L 40%
of the EPA limit 1300 µg/L
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2017
1/1 SYR4
Total Haloacetic Acids (HAA5)
32.1 µg/L 54%
of the EPA limit 60 µg/L
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2019
1/1 SYR4
TTHM
24.15499999999999 µg/L 30%
of the EPA limit 80 µg/L
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2019
1/1 SYR4
Dichloroacetic Acid
23.375 µg/L
No EPA limit set
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2019
1/1 SYR4
Lead
22 µg/L 147%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2017
1/1 SYR4
Chloroform
15.625 µg/L
No EPA limit set
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2019
1/1 SYR4
Bromodichloromethane
7.304999999999999 µg/L
No EPA limit set
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2019
1/1 SYR4
Dibromochloromethane
6.774999999999999 µg/L
No EPA limit set
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2019
1/1 SYR4
Monochloroacetic Acid
5.3 µg/L
No EPA limit set
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2019
1/1 SYR4
Trichloroacetic Acid
5.079999999999999 µg/L
No EPA limit set
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2019
1/1 SYR4
Bromoform
4.824999999999999 µg/L
No EPA limit set
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2019
1/1 SYR4
Dibromoacetic Acid
2.2 µg/L
No EPA limit set
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2019
1/1 SYR4
Benzo(A)Pyrene
0.0200 µg/L 10%
of the EPA limit 0.2000 µg/L
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2018
1/1 SYR4
PFOS
0.0043 µg/L
No EPA limit set
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2025
1/1 UCMR-5
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
Main supplier: GREENE CO REGIONAL WATER SYST · 11,026 people · 2028
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 28554

SupplierStatePopulation served
GREENE CO REGIONAL WATER SYST NC 11,026

Frequently asked questions about ZIP 28554 tap water

Is the tap water in ZIP 28554 safe to drink?

EPA testing detected 16 contaminants across the water suppliers serving ZIP 28554. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 28554?

1 public water supplier report EPA drinking-water monitoring for ZIP 28554. Each is listed above with its population served.

What contaminants are in ZIP 28554's water?

EPA monitoring detected Fluoride, Copper, Total Haloacetic Acids (HAA5), TTHM, Dichloroacetic Acid, and others across this ZIP's suppliers. The full list with levels and sources is above.