← Kinston, NC

Tap water quality report

ZIP 28503 — Kinston, NC

EPA monitoring across the 2 water suppliers serving ZIP 28503 in Kinston, NC detected 23 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

2
water suppliers
29,690
people served
23
contaminants found

What was found in ZIP 28503

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Lead
958 µg/L 6387%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2018
2/2 SYR4
Fluoride
454 µg/L 11%
of the EPA limit 4000 µg/L
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
1/2 SYR4
Copper
158.25 µg/L 12%
of the EPA limit 1300 µg/L
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2018
Highest in the ZIP: 277.75 µg/L — DEEP RUN WATER CORPORATION · 14,196 people · 2017
2/2 SYR4
TTHM
39 µg/L 49%
of the EPA limit 80 µg/L
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
Highest in the ZIP: 51.39999999999998 µg/L — DEEP RUN WATER CORPORATION · 14,196 people · 2019
2/2 SYR4
Total Haloacetic Acids (HAA5)
36.85499999999999 µg/L 61%
of the EPA limit 60 µg/L
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
2/2 SYR4
Chloroform
25.06 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
Highest in the ZIP: 29.244999999999987 µg/L — DEEP RUN WATER CORPORATION · 14,196 people · 2019
2/2 SYR4
Dichloroacetic Acid
24.904999999999998 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
2/2 SYR4
Bromodichloromethane
11.035 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
Highest in the ZIP: 11.15 µg/L — DEEP RUN WATER CORPORATION · 14,196 people · 2019
2/2 SYR4
Trichloroacetic Acid
8.5 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
2/2 SYR4
Dibromochloromethane
3.879999999999998 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
Highest in the ZIP: 4.05 µg/L — DEEP RUN WATER CORPORATION · 14,196 people · 2019
2/2 SYR4
Monochloroacetic Acid
3.9599999999999995 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
2/2 SYR4
Dibromoacetic Acid
1.9799999999999998 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
2/2 SYR4
Di(2-ethylhexyl) Phthalate
1.6 µg/L 27%
of the EPA limit 6 µg/L
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
1/2 SYR4
Xylenes, Total
0.7000 µg/L 0%
of the EPA limit 10000 µg/L
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
1/2 SYR4
Benzo(A)Pyrene
0.0400 µg/L 20%
of the EPA limit 0.2000 µg/L
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2019
1/2 SYR4
PFOS
0.0101 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2024
Highest in the ZIP: 0.0115 µg/L — DEEP RUN WATER CORPORATION · 14,196 people · 2025
2/2 UCMR-5
Pfba
0.0077 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2024
2/2 UCMR-5
Pfpea
0.0072 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2024
2/2 UCMR-5
PFOA
0.0060 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2024
Highest in the ZIP: 0.0070 µg/L — DEEP RUN WATER CORPORATION · 14,196 people · 2025
2/2 UCMR-5
Pfhxa
0.0068 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2024
2/2 UCMR-5
PFHXS
0.0068 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2024
2/2 UCMR-5
PFBS
0.0048 µg/L
No EPA limit set
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2024
2/2 UCMR-5
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
Main supplier: NORTH LENOIR WATER CORP · 15,494 people · 2025
2/2 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 28503

SupplierStatePopulation served
NORTH LENOIR WATER CORP NC 15,494
DEEP RUN WATER CORPORATION NC 14,196

Frequently asked questions about ZIP 28503 tap water

Is the tap water in ZIP 28503 safe to drink?

EPA testing detected 23 contaminants across the water suppliers serving ZIP 28503. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 28503?

2 public water suppliers report EPA drinking-water monitoring for ZIP 28503. Each is listed above with its population served.

What contaminants are in ZIP 28503's water?

EPA monitoring detected Lead, Fluoride, Copper, TTHM, Total Haloacetic Acids (HAA5), and others across this ZIP's suppliers. The full list with levels and sources is above.