← Northampton, PA

Tap water quality report

ZIP 18052 — Northampton, PA

EPA monitoring across the 3 water suppliers serving ZIP 18052 in Northampton, PA detected 40 contaminants. A detection doesn't automatically mean the water is unsafe — see the highest level found below, with the EPA limit for each.

3
water suppliers
67,563
people served
40
contaminants found

What was found in ZIP 18052

The highest level seen across the suppliers serving this ZIP, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
6600 µg/L 66%
of the EPA limit 10000 µg/L
3/3 SYR4
Copper
858 µg/L 66%
of the EPA limit 1300 µg/L
3/3 SYR4
Fluoride
790 µg/L 20%
of the EPA limit 4000 µg/L
2/3 SYR4
TTHM
99.9 µg/L 125%
of the EPA limit, in the worst sample — 80 µg/L
3/3 SYR4
Chloroform
91.4 µg/L
No EPA limit set
3/3 SYR4
Total Haloacetic Acids (HAA5)
81.1 µg/L 135%
of the EPA limit, in the worst sample — 60 µg/L
3/3 SYR4
Barium
67 µg/L 3.4%
of the EPA limit 2000 µg/L
3/3 SYR4
Lead
47 µg/L 313%
of the EPA limit, in the worst sample — 15 µg/L
3/3 SYR4
Trichloroacetic Acid
28 µg/L
No EPA limit set
2/3 SYR4
Dichloroacetic Acid
27.7 µg/L
No EPA limit set
2/3 SYR4
Bromodichloromethane
19 µg/L
No EPA limit set
3/3 SYR4
Cyanide
13 µg/L 6.5%
of the EPA limit 200 µg/L
3/3 SYR4
Dibromochloromethane
9.7 µg/L
No EPA limit set
3/3 SYR4
Selenium
4 µg/L 8%
of the EPA limit 50 µg/L
3/3 SYR4
cis-1,2-Dichloroethylene
3.7 µg/L 5.3%
of the EPA limit 70 µg/L
1/3 SYR4
Bromoform
3.2 µg/L
No EPA limit set
1/3 SYR4
Xylenes, Total
3.2 µg/L 0%
of the EPA limit 10000 µg/L
1/3 SYR4
Chromium
3 µg/L 3%
of the EPA limit 100 µg/L
2/3 SYR4
Nitrite
3 µg/L 0.3%
of the EPA limit 1000 µg/L
3/3 SYR4
trans-1,2-Dichloroethylene
3 µg/L 3%
of the EPA limit 100 µg/L
1/3 SYR4
Trichloroethylene
2.06 µg/L 41%
of the EPA limit 5 µg/L
1/3 SYR4
Dibromoacetic Acid
1.97 µg/L
No EPA limit set
1/3 SYR4
Combined Uranium
1.26501 µg/L 4.2%
of the EPA limit 30 µg/L
2/3 SYR4
1,1,1-Trichloroethane
1.1 µg/L 0.6%
of the EPA limit 200 µg/L
1/3 SYR4
Di(2-ethylhexyl) Phthalate
1.1 µg/L 18%
of the EPA limit 6 µg/L
1/3 SYR4
Benzene
0.9000 µg/L 18%
of the EPA limit 5 µg/L
1/3 SYR4
Arsenic
0.6000 µg/L 6%
of the EPA limit 10 µg/L
1/3 SYR4
Ethylbenzene
0.6000 µg/L 0.1%
of the EPA limit 700 µg/L
1/3 SYR4
Dichloromethane
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/3 SYR4
Mercury
0.1000 µg/L 5%
of the EPA limit 2 µg/L
1/3 SYR4
Thallium, Total
0.0300 µg/L 1.5%
of the EPA limit 2 µg/L
1/3 SYR4
Pfpea
0.0152 µg/L
No EPA limit set
2/3 UCMR-5
PFHXS
0.0070 µg/L
No EPA limit set
1/3 UCMR-5
Pfhxa
0.0066 µg/L
No EPA limit set
2/3 UCMR-5
PFNA
0.0061 µg/L
No EPA limit set
1/3 UCMR-5
Lead
0.0060 mg/L 40%
of the EPA limit 0.0150 mg/L
3/3 LCR
PFOS
0.0054 µg/L
No EPA limit set
1/3 UCMR-5
Pfba
0.0052 µg/L
No EPA limit set
1/3 UCMR-5
PFOA
0.0049 µg/L
No EPA limit set
2/3 UCMR-5
PFBS
0.0037 µg/L
No EPA limit set
1/3 UCMR-5
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 18052

SupplierStatePopulation served
NORTHAMPTON BORO MUNI AUTH PA 40,000
SWT MAIN SYSTEM PA 14,500
WHITEHALL TWP AUTHORITY PA 13,063

Frequently asked questions about ZIP 18052 tap water

Is the tap water in ZIP 18052 safe to drink?

EPA testing detected 40 contaminants across the water suppliers serving ZIP 18052. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 18052?

3 public water suppliers report EPA drinking-water monitoring for ZIP 18052. Each is listed above with its population served.

What contaminants are in ZIP 18052's water?

EPA monitoring detected Nitrate, Copper, Fluoride, TTHM, Chloroform, and others across this ZIP's suppliers. The full list with levels and sources is above.