← Indiana, PA

Tap water quality report

ZIP 15701 — Indiana, PA

EPA monitoring across the 3 water suppliers serving ZIP 15701 in Indiana, PA detected 21 contaminants. A detection doesn't automatically mean the water is unsafe — see the highest level found below, with the EPA limit for each.

3
water suppliers
36,918
people served
21
contaminants found

What was found in ZIP 15701

The highest level seen across the suppliers serving this ZIP, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
3040 µg/L 30%
of the EPA limit 10000 µg/L
3/3 SYR4
Fluoride
740 µg/L 19%
of the EPA limit 4000 µg/L
3/3 SYR4
Copper
423 µg/L 33%
of the EPA limit 1300 µg/L
3/3 SYR4
Total Haloacetic Acids (HAA5)
220 µg/L 367%
of the EPA limit, in the worst sample — 60 µg/L
3/3 SYR4
TTHM
164 µg/L 205%
of the EPA limit, in the worst sample — 80 µg/L
3/3 SYR4
Chloroform
114.7 µg/L
No EPA limit set
3/3 SYR4
Monochloroacetic Acid
100 µg/L
No EPA limit set
2/3 SYR4
Nitrite
100 µg/L 10%
of the EPA limit 1000 µg/L
1/3 SYR4
Trichloroacetic Acid
67 µg/L
No EPA limit set
3/3 SYR4
Bromodichloromethane
54.2 µg/L
No EPA limit set
3/3 SYR4
Barium
51 µg/L 2.6%
of the EPA limit 2000 µg/L
2/3 SYR4
Dichloroacetic Acid
46 µg/L
No EPA limit set
3/3 SYR4
Dibromochloromethane
43.7 µg/L
No EPA limit set
3/3 SYR4
Arsenic
38.5 µg/L 385%
of the EPA limit, in the worst sample — 10 µg/L
1/3 SYR4
Lead
29.7 µg/L 198%
of the EPA limit, in the worst sample — 15 µg/L
3/3 SYR4
Lithium
13.5 µg/L
No EPA limit set
1/3 UCMR-5
Bromoform
7.6 µg/L
No EPA limit set
1/3 SYR4
Dibromoacetic Acid
1.6 µg/L
No EPA limit set
2/3 SYR4
Atrazine
1 µg/L 33%
of the EPA limit 3 µg/L
2/3 SYR4
Monobromoacetic Acid
0.3600 µg/L
No EPA limit set
1/3 SYR4
Lead
0.0019 mg/L 13%
of the EPA limit 0.0150 mg/L
3/3 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 15701

SupplierStatePopulation served
PA AMERICAN WATER CO-INDIANA D PA 22,360
ICMSA CROOKED CREEK PA 9,638
CENTRAL INDIANA CO WATER AUTH PA 4,920

Frequently asked questions about ZIP 15701 tap water

Is the tap water in ZIP 15701 safe to drink?

EPA testing detected 21 contaminants across the water suppliers serving ZIP 15701. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 15701?

3 public water suppliers report EPA drinking-water monitoring for ZIP 15701. Each is listed above with its population served.

What contaminants are in ZIP 15701's water?

EPA monitoring detected Nitrate, Fluoride, Copper, Total Haloacetic Acids (HAA5), TTHM, and others across this ZIP's suppliers. The full list with levels and sources is above.