Tap water quality report

Wvawc Bluestone Plant

EPA monitoring tested this supplier for 68 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

68
contaminants tested
16
detected
20,562
people served
0
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Summers

Compliance record

No violations on file. The EPA has no formal drinking-water violations recorded for this supplier.

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
13.8 µg/L
No EPA limit set
129/129 SYR4 2012–2019
Chloroform
106 µg/L
No EPA limit set
129/129 SYR4 2012–2019
Dichloroacetic Acid
35.1 µg/L
No EPA limit set
129/129 SYR4 2012–2019
TTHM
121.2 µg/L 152%
of the EPA limit, in the worst sample — 80 µg/L
129/129 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
67.3 µg/L 112%
of the EPA limit, in the worst sample — 60 µg/L
129/129 SYR4 2012–2019
Trichloroacetic Acid
29.6 µg/L
No EPA limit set
129/129 SYR4 2012–2019
Dibromochloromethane
2 µg/L
No EPA limit set
85/129 SYR4 2012–2019
Copper
311 µg/L 24%
of the EPA limit 1300 µg/L
62/90 SYR4 2012–2018
Monobromoacetic Acid
10.6 µg/L
No EPA limit set
54/129 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
21/21 LCR 2025
Nitrate
910 µg/L 9.1%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Monochloroacetic Acid
14.4 µg/L
No EPA limit set
15/129 SYR4 2012–2019
Lead
65 µg/L 433%
of the EPA limit, in the worst sample — 15 µg/L
14/90 SYR4 2012–2018
Fluoride
800 µg/L 20%
of the EPA limit 4000 µg/L
8/8 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
0.2000 pCi/L 1.3%
of the EPA limit 15 pCi/L
1/1 SYR4 2019
Nitrate-Nitrite
750 µg/L 7.5%
of the EPA limit 10000 µg/L
1/1 SYR4 2019
52 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidEthylbenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)TrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Frequently asked questions about Wvawc Bluestone Plant

Is Wvawc Bluestone Plant tap water safe to drink?

EPA monitoring detected 16 contaminants in Wvawc Bluestone Plant's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Wvawc Bluestone Plant's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Wvawc Bluestone Plant serve?

Wvawc Bluestone Plant reports serving 20,562 people, per its EPA record.

Has Wvawc Bluestone Plant had any water quality violations?

The EPA has no formal drinking-water violations on file for Wvawc Bluestone Plant.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.