Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 1998-08-01 → 1998-08-31 |
| MCL | Health-based | Resolved | 1998-08-01 → 1998-08-31 |
| MCL | Health-based | Resolved | 1998-08-01 → 1998-08-31 |
| MCL | Health-based | Resolved | 1998-08-01 → 1998-08-31 |
| MCL | Health-based | Resolved | 1998-07-01 → 1998-07-31 |
| MCL | Health-based | Resolved | 1998-07-01 → 1998-07-31 |
| MCL | Health-based | Resolved | 1998-07-01 → 1998-07-31 |
| MCL | Health-based | Resolved | 1998-07-01 → 1998-07-31 |
| MR | Monitoring | Archived | 2025-12-01 → 2025-12-31 |
| MR | Monitoring | Archived | 2025-12-01 → 2025-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1100 µg/L 85% of the EPA limit 1300 µg/L | 30/30 | SYR4 | 2014–2017 |
| Lead | 28.8 µg/L 192% of the EPA limit, in the worst sample — 15 µg/L | 30/30 | SYR4 | 2014–2017 |
| Lead | 0.0029 mg/L 19% of the EPA limit 0.0150 mg/L | 16/16 | LCR | 2023 |
| Bromodichloromethane | 94.3 µg/L No EPA limit set | 14/14 | SYR4 | 2013–2019 |
| Bromoform | 9.9 µg/L No EPA limit set | 14/14 | SYR4 | 2013–2019 |
| Chloroform | 150 µg/L No EPA limit set | 14/14 | SYR4 | 2013–2019 |
| Dibromochloromethane | 33 µg/L No EPA limit set | 14/14 | SYR4 | 2013–2019 |
| TTHM | 286 µg/L 358% of the EPA limit, in the worst sample — 80 µg/L | 14/14 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 106 µg/L 177% of the EPA limit, in the worst sample — 60 µg/L | 14/14 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 11.4 µg/L No EPA limit set | 12/14 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 51.1 µg/L No EPA limit set | 12/14 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 22.6 µg/L No EPA limit set | 8/14 | SYR4 | 2013–2019 |
| Nitrate | 3800 µg/L 38% of the EPA limit 10000 µg/L | 4/20 | SYR4 | 2012–2019 |
| Barium | 744 µg/L 37% of the EPA limit 2000 µg/L | 3/3 | SYR4 | 2013–2019 |
| Fluoride | 260 µg/L 6.5% of the EPA limit 4000 µg/L | 3/3 | SYR4 | 2013–2019 |
| Gross Alpha, Excl. Radon And U | 3 pCi/L 20% of the EPA limit 15 pCi/L | 3/3 | SYR4 | 2013–2019 |
| Monochloroacetic Acid | 21 µg/L No EPA limit set | 2/14 | SYR4 | 2013–2019 |
| Xylenes, Total | 0.3800 µg/L 0% of the EPA limit 10000 µg/L | 1/5 | SYR4 | 2012–2019 |
60 contaminants tested, none detected
Utility contact
Frequently asked questions about Preston County Psd 4
Is Preston County Psd 4 tap water safe to drink?
EPA monitoring detected 18 contaminants in Preston County Psd 4's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Preston County Psd 4's water?
EPA monitoring detected Copper, Lead, Lead, Bromodichloromethane, Bromoform, and others. The full list with the level and data source for each is above.
How many people does Preston County Psd 4 serve?
Preston County Psd 4 reports serving 8,753 people in West Virginia, per its EPA record.
Has Preston County Psd 4 had any water quality violations?
The EPA has 133 violations on file for Preston County Psd 4, of which 8 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.