Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Unaddressed | 2026-01-01 |
| TT | Health-based | Unaddressed | 2026-01-01 |
| TT | Health-based | Resolved | 2023-08-27 |
| TT | Health-based | Resolved | 2023-08-27 |
| TT | Health-based | Resolved | 2023-08-27 |
| TT | Health-based | Resolved | 2020-12-27 |
| TT | Health-based | Resolved | 2020-12-27 |
| TT | Health-based | Resolved | 2020-12-27 |
| TT | Health-based | Resolved | 2020-10-05 |
| TT | Health-based | Resolved | 2020-10-05 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 32 µg/L No EPA limit set | 132/132 | SYR4 | 2012–2019 |
| Chloroform | 103 µg/L No EPA limit set | 132/132 | SYR4 | 2012–2019 |
| TTHM | 133 µg/L 166% of the EPA limit, in the worst sample — 80 µg/L | 131/131 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 45 µg/L No EPA limit set | 130/130 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 82 µg/L 137% of the EPA limit, in the worst sample — 60 µg/L | 130/130 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 36.6 µg/L No EPA limit set | 130/130 | SYR4 | 2012–2019 |
| Dibromochloromethane | 22 µg/L No EPA limit set | 109/132 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 6 µg/L No EPA limit set | 69/130 | SYR4 | 2012–2019 |
| Copper | 975 µg/L 75% of the EPA limit 1300 µg/L | 60/60 | SYR4 | 2014–2017 |
| Monochloroacetic Acid | 12.5 µg/L No EPA limit set | 48/130 | SYR4 | 2012–2019 |
| Lead | 73 µg/L 487% of the EPA limit, in the worst sample — 15 µg/L | 35/60 | SYR4 | 2014–2017 |
| Monobromoacetic Acid | 6.8 µg/L No EPA limit set | 22/130 | SYR4 | 2012–2019 |
| Nitrate | 676 µg/L 6.8% of the EPA limit 10000 µg/L | 18/18 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 16/16 | LCR | 2025 |
| Bromoform | 3 µg/L No EPA limit set | 12/132 | SYR4 | 2012–2019 |
| Fluoride | 1390 µg/L 35% of the EPA limit 4000 µg/L | 11/12 | SYR4 | 2012–2019 |
| Barium | 60 µg/L 3% of the EPA limit 2000 µg/L | 8/8 | SYR4 | 2012–2019 |
| Selenium | 2.56 µg/L 5.1% of the EPA limit 50 µg/L | 7/8 | SYR4 | 2012–2019 |
| Cyanide | 70.5 µg/L 35% of the EPA limit 200 µg/L | 6/8 | SYR4 | 2012–2019 |
| Antimony, Total | 0.3300 µg/L 5.5% of the EPA limit 6 µg/L | 3/8 | SYR4 | 2012–2019 |
| Chromium | 1.56 µg/L 1.6% of the EPA limit 100 µg/L | 2/8 | SYR4 | 2012–2019 |
| Mercury | 0.2000 µg/L 10% of the EPA limit 2 µg/L | 2/8 | SYR4 | 2012–2019 |
| Cadmium | 0.1774 µg/L 3.5% of the EPA limit 5 µg/L | 1/8 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 1.01 pCi/L 6.7% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2019 |
51 contaminants tested, none detected
Frequently asked questions about Logan County Psd - Northern Regional
Is Logan County Psd - Northern Regional tap water safe to drink?
EPA monitoring detected 24 contaminants in Logan County Psd - Northern Regional's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Logan County Psd - Northern Regional's water?
EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Dichloroacetic Acid, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Logan County Psd - Northern Regional serve?
Logan County Psd - Northern Regional reports serving 16,921 people, per its EPA record.
Has Logan County Psd - Northern Regional had any water quality violations?
The EPA has 385 violations on file for Logan County Psd - Northern Regional, of which 33 are health-based (a contaminant limit or required treatment was breached) and 31 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.