Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 2026-01-01 → 2026-03-31 |
| MCL | Health-based | Resolved | 2013-04-01 → 2013-06-30 |
| MCL | Health-based | Resolved | 2013-04-01 → 2013-06-30 |
| MCL | Health-based | Resolved | 2013-04-01 → 2013-06-30 |
| MCL | Health-based | Resolved | 2013-04-01 → 2013-06-30 |
| MCL | Health-based | Resolved | 2013-04-01 → 2013-06-30 |
| MCL | Health-based | Resolved | 2013-01-01 → 2013-03-31 |
| MCL | Health-based | Resolved | 2013-01-01 → 2013-03-31 |
| MCL | Health-based | Resolved | 2013-01-01 → 2013-03-31 |
| MCL | Health-based | Resolved | 2013-01-01 → 2013-03-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Combined Radium (-226 And -228) | 9.3725 pCi/L 187% of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 10.37 pCi/L | 16/16 | SYR4 | 2012–2019 |
| Nitrate | 3200 µg/L 32% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Copper | 641 µg/L 49% of the EPA limit 1300 µg/L
worst single sample: 690 µg/L | 15/15 | SYR4 | 2012–2018 |
| Lead | 0.0073 mg/L 49% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2025 |
| Lead | 5.32 µg/L 35% of the EPA limit 15 µg/L
worst single sample: 5.6 µg/L | 8/15 | SYR4 | 2012–2018 |
| Gross Alpha, Excl. Radon And U | 13.465 pCi/L 90% of the EPA limit 15 pCi/L
worst single sample: 13.9 pCi/L | 4/4 | SYR4 | 2012–2019 |
| Bromodichloromethane | 1.38 µg/L No EPA limit set
worst single sample: 1.4 µg/L | 3/4 | SYR4 | 2013–2019 |
| TTHM | 2.58 µg/L 3.2% of the EPA limit 80 µg/L
worst single sample: 2.61 µg/L | 3/3 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 0.9540 µg/L 1.6% of the EPA limit 60 µg/L
worst single sample: 0.9900 µg/L | 3/3 | SYR4 | 2013–2019 |
| Dibromochloromethane | 0.7605 µg/L No EPA limit set
worst single sample: 0.7700 µg/L | 2/4 | SYR4 | 2013–2019 |
| Barium | 33 µg/L 1.7% of the EPA limit 2000 µg/L | 1/1 | SYR4 | 2018 |
| Dibromoacetic Acid | 0.4100 µg/L No EPA limit set | 1/3 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 0.5800 µg/L No EPA limit set | 1/3 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 3100 µg/L 31% of the EPA limit 10000 µg/L | 1/1 | SYR4 | 2018 |
60 contaminants tested, none detected
Utility contact
Frequently asked questions about Villa Diann Mhp
Is Villa Diann Mhp tap water safe to drink?
EPA monitoring detected 14 contaminants in Villa Diann Mhp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Villa Diann Mhp's water?
EPA monitoring detected Combined Radium (-226 And -228), Nitrate, Copper, Lead, Lead, and others. The full list with the level and data source for each is above.
How many people does Villa Diann Mhp serve?
Villa Diann Mhp reports serving 420 people in Wisconsin, per its EPA record.
Has Villa Diann Mhp had any water quality violations?
The EPA has 65 violations on file for Villa Diann Mhp, of which 35 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.