← Wisconsin

Tap water quality report

Holy Family Convent

EPA monitoring tested this supplier for 63 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

63
contaminants tested
10
detected
195
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Manitowoc

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
8
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2004-03-01 → 2004-03-31
MR Monitoring Resolved 2004-03-01 → 2004-03-31
MR Monitoring Resolved 2004-03-01 → 2004-03-31
MR Monitoring Resolved 2004-03-01 → 2004-03-31
MR Monitoring Resolved 2004-03-01 → 2004-03-31
MR Monitoring Resolved 2004-03-01 → 2004-03-31
MR Monitoring Resolved 1998-12-01 → 1998-12-31
MR Monitoring Resolved 1998-12-01 → 1998-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0040 mg/L 27%
of the EPA limit 0.0150 mg/L
17/17 LCR 2024
Copper
713 µg/L 55%
of the EPA limit 1300 µg/L
15/15 SYR4 2012–2018
Lead
13 µg/L 87%
of the EPA limit 15 µg/L
15/15 SYR4 2012–2018
Nitrate
430 µg/L 4.3%
of the EPA limit 10000 µg/L
12/14 SYR4 2012–2019
Barium
140 µg/L 7%
of the EPA limit 2000 µg/L
1/1 SYR4 2018
Chromium
0.7000 µg/L 0.7%
of the EPA limit 100 µg/L
1/1 SYR4 2018
Combined Uranium
0.4590 µg/L 1.5%
of the EPA limit 30 µg/L
1/1 SYR4 2018
Fluoride
200 µg/L 5%
of the EPA limit 4000 µg/L
1/1 SYR4 2018
Gross Alpha, Excl. Radon And U
0.4150 pCi/L 2.8%
of the EPA limit 15 pCi/L
1/1 SYR4 2018
Nitrate-Nitrite
240 µg/L 2.4%
of the EPA limit 10000 µg/L
1/1 SYR4 2018
53 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDinosebDiquatEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Frequently asked questions about Holy Family Convent

Is Holy Family Convent tap water safe to drink?

EPA monitoring detected 10 contaminants in Holy Family Convent's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Holy Family Convent's water?

EPA monitoring detected Lead, Copper, Lead, Nitrate, Barium, and others. The full list with the level and data source for each is above.

How many people does Holy Family Convent serve?

Holy Family Convent reports serving 195 people in Wisconsin, per its EPA record.

Has Holy Family Convent had any water quality violations?

The EPA has 8 violations on file for Holy Family Convent, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.