← Wisconsin

Tap water quality report

Wells St Station 425 West

EPA monitoring tested this supplier for 76 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

76
contaminants tested
17
detected
25
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Waukesha

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
16
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2023-07-01
Other Monitoring Resolved 2023-07-01
MR Monitoring Resolved 2017-01-01 → 2017-12-31
MR Monitoring Resolved 2017-01-01 → 2017-12-31
MR Monitoring Resolved 2017-01-01 → 2017-12-31
MR Monitoring Resolved 2017-01-01 → 2017-12-31
MR Monitoring Resolved 2017-01-01 → 2017-12-31
MR Monitoring Resolved 2017-01-01 → 2017-12-31
MR Monitoring Resolved 2017-01-01 → 2017-12-31
MR Monitoring Resolved 2017-01-01 → 2017-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
112.5 µg/L 8.7%
of the EPA limit 1300 µg/L
worst single sample: 160 µg/L
20/21 SYR4 2015–2018
Combined Radium (-226 And -228)
1.5015 pCi/L 30%
of the EPA limit 5 pCi/L
worst single sample: 1.502 pCi/L
6/6 SYR4 2015–2016
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
5/5 LCR 2024
Barium
314.608 µg/L 16%
of the EPA limit 2000 µg/L
worst single sample: 370 µg/L
4/4 SYR4 2015–2018
Fluoride
398 µg/L 10%
of the EPA limit 4000 µg/L
worst single sample: 410 µg/L
4/4 SYR4 2015–2018
Toluene
16.44 µg/L 1.6%
of the EPA limit 1000 µg/L
worst single sample: 18 µg/L
4/9 SYR4 2015–2019
Lead
1.199 µg/L 8%
of the EPA limit 15 µg/L
worst single sample: 1.3 µg/L
3/20 SYR4 2015–2018
TTHM
1.329 µg/L 1.7%
of the EPA limit 80 µg/L
worst single sample: 1.36 µg/L
3/3 SYR4 2016–2019
Dichloroacetic Acid
0.6765 µg/L
No EPA limit set
worst single sample: 0.6900 µg/L
2/3 SYR4 2016–2019
Total Haloacetic Acids (HAA5)
1.0875 µg/L 1.8%
of the EPA limit 60 µg/L
worst single sample: 1.09 µg/L
2/3 SYR4 2016–2019
Arsenic
1.2 µg/L 12%
of the EPA limit 10 µg/L
1/3 SYR4 2015–2018
Bromodichloromethane
0.3400 µg/L
No EPA limit set
1/5 SYR4 2016–2019
Chromium
1.55 µg/L 1.6%
of the EPA limit 100 µg/L
1/3 SYR4 2015–2018
Dibromoacetic Acid
0.1700 µg/L
No EPA limit set
1/3 SYR4 2016–2019
Gross Alpha, Excl. Radon And U
1.1 pCi/L 7.3%
of the EPA limit 15 pCi/L
1/1 SYR4 2015
Monobromoacetic Acid
0.2500 µg/L
No EPA limit set
1/3 SYR4 2016–2019
Trichloroacetic Acid
0.2500 µg/L
No EPA limit set
1/3 SYR4 2016–2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformDichloromethaneDalaponDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNitrateNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Frequently asked questions about Wells St Station 425 West

Is Wells St Station 425 West tap water safe to drink?

EPA monitoring detected 17 contaminants in Wells St Station 425 West's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Wells St Station 425 West's water?

EPA monitoring detected Copper, Combined Radium (-226 And -228), Lead, Barium, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Wells St Station 425 West serve?

Wells St Station 425 West reports serving 25 people in Wisconsin, per its EPA record.

Has Wells St Station 425 West had any water quality violations?

The EPA has 16 violations on file for Wells St Station 425 West, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.