Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2024-06-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-06-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-06-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-06-01 → 2024-06-30 |
| MCL | Health-based | Resolved | 2024-06-01 → 2024-06-30 |
| Other | Monitoring | Resolved | 2023-07-01 |
| Other | Monitoring | Resolved | 2023-07-01 |
| Other | Monitoring | Resolved | 2023-07-01 |
| Other | Monitoring | Resolved | 2023-07-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 46.2 µg/L 3.6% of the EPA limit 1300 µg/L
worst single sample: 48 µg/L | 19/20 | SYR4 | 2016–2019 |
| Lead | 1.4265 µg/L 9.5% of the EPA limit 15 µg/L
worst single sample: 2.4 µg/L | 12/21 | SYR4 | 2016–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 7/7 | LCR | 2024 |
| Combined Radium (-226 And -228) | 1.932 pCi/L 39% of the EPA limit 5 pCi/L
worst single sample: 1.98 pCi/L | 4/4 | SYR4 | 2016–2017 |
| Gross Alpha, Excl. Radon And U | 2.93317 pCi/L 20% of the EPA limit 15 pCi/L
worst single sample: 3.01667 pCi/L | 4/4 | SYR4 | 2016–2017 |
| Barium | 179 µg/L 9% of the EPA limit 2000 µg/L
worst single sample: 180 µg/L | 2/2 | SYR4 | 2016–2018 |
| Fluoride | 319 µg/L 8% of the EPA limit 4000 µg/L
worst single sample: 320 µg/L | 2/2 | SYR4 | 2016–2018 |
| Nitrate | 60 µg/L 0.6% of the EPA limit 10000 µg/L | 2/6 | SYR4 | 2016–2019 |
| Antimony, Total | 1.1 µg/L 18% of the EPA limit 6 µg/L | 1/2 | SYR4 | 2016–2018 |
| Arsenic | 6.6 µg/L 66% of the EPA limit 10 µg/L | 1/2 | SYR4 | 2016–2018 |
| Combined Uranium | 0.2300 µg/L 0.8% of the EPA limit 30 µg/L | 1/1 | SYR4 | 2016 |
| Nitrate-Nitrite | 110 µg/L 1.1% of the EPA limit 10000 µg/L | 1/1 | SYR4 | 2018 |
52 contaminants tested, none detected
Utility contact
Frequently asked questions about Sanctuary of Delafield
Is Sanctuary of Delafield tap water safe to drink?
EPA monitoring detected 12 contaminants in Sanctuary of Delafield's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Sanctuary of Delafield's water?
EPA monitoring detected Copper, Lead, Lead, Combined Radium (-226 And -228), Gross Alpha, Excl. Radon And U, and others. The full list with the level and data source for each is above.
How many people does Sanctuary of Delafield serve?
Sanctuary of Delafield reports serving 27 people in Wisconsin, per its EPA record.
Has Sanctuary of Delafield had any water quality violations?
The EPA has 9 violations on file for Sanctuary of Delafield, of which 5 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.