Tap water quality report

Wind Point Water Dept

EPA monitoring tested this supplier for 14 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
13
detected
1,804
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Racine

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
97
violations on file
2
still open
ViolationTypeStatusPeriod
Other Monitoring Unaddressed 2024-10-17
Other Monitoring Unaddressed 2024-10-17
Other Monitoring Resolved 2023-10-01
Other Monitoring Resolved 2023-10-01
MR Monitoring Resolved 2023-06-01
MR Monitoring Resolved 2023-06-01
MR Monitoring Resolved 2023-06-01
MR Monitoring Resolved 2023-06-01
Other Monitoring Resolved 2021-10-15
Other Monitoring Resolved 2021-10-15

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
15 µg/L
No EPA limit set
worst single sample: 16 µg/L
31/31 SYR4 2012–2019
Chloroform
31 µg/L
No EPA limit set
worst single sample: 36 µg/L
31/31 SYR4 2012–2019
Dibromochloromethane
8.7 µg/L
No EPA limit set
worst single sample: 8.9 µg/L
31/31 SYR4 2012–2019
TTHM
55.85 µg/L 70%
of the EPA limit 80 µg/L
worst single sample: 58.2 µg/L
31/31 SYR4 2012–2019
Dichloroacetic Acid
13.55 µg/L
No EPA limit set
worst single sample: 15 µg/L
30/30 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
24.321 µg/L 41%
of the EPA limit 60 µg/L
worst single sample: 25.3 µg/L
30/30 SYR4 2012–2019
Trichloroacetic Acid
9.235 µg/L
No EPA limit set
worst single sample: 13 µg/L
30/30 SYR4 2012–2019
Dibromoacetic Acid
1.67 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
27/30 SYR4 2012–2019
Bromoform
1.195 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
22/31 SYR4 2012–2019
Lead
0.0014 mg/L 9.3%
of the EPA limit 0.0150 mg/L
13/13 LCR 2024
Copper
301.5 µg/L 23%
of the EPA limit 1300 µg/L
worst single sample: 342 µg/L
11/20 SYR4 2014–2017
Lead
15.7 µg/L 105%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 17 µg/L
3/20 SYR4 2014–2017
Monochloroacetic Acid
2.74 µg/L
No EPA limit set
worst single sample: 2.8 µg/L
3/30 SYR4 2012–2019
1 contaminants tested, none detected
Monobromoacetic Acid

Utility contact

Frequently asked questions about Wind Point Water Dept

Is Wind Point Water Dept tap water safe to drink?

EPA monitoring detected 13 contaminants in Wind Point Water Dept's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Wind Point Water Dept's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Wind Point Water Dept serve?

Wind Point Water Dept reports serving 1,804 people in Wisconsin, per its EPA record.

Has Wind Point Water Dept had any water quality violations?

The EPA has 97 violations on file for Wind Point Water Dept, of which 0 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.