Heidel Rd Apts 139

EPA monitoring tested this supplier for 63 contaminants and detected 8. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

63
contaminants tested
8
detected
40
people served
8
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Ozaukee

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
127
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-04-11
TT Health-based Resolved 2024-04-11
TT Health-based Resolved 2024-04-11
TT Health-based Resolved 2024-04-11
TT Health-based Resolved 2020-10-25
TT Health-based Resolved 2020-10-25
TT Health-based Resolved 2020-10-25
TT Health-based Resolved 2020-10-25
RPT Monitoring Unaddressed 2025-07-02
RPT Monitoring Resolved 2024-04-11

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
198 µg/L 15%
of the EPA limit 1300 µg/L
worst single sample: 350 µg/L
25/25 SYR4 2012–2018
Lead
17.42 µg/L 116%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 67 µg/L
25/25 SYR4 2012–2018
Lead
0.0060 mg/L 40%
of the EPA limit 0.0150 mg/L
15/15 LCR 2024
Arsenic
3.86 µg/L 39%
of the EPA limit 10 µg/L
worst single sample: 4 µg/L
3/3 SYR4 2012–2018
Barium
128 µg/L 6.4%
of the EPA limit 2000 µg/L
worst single sample: 130 µg/L
3/3 SYR4 2012–2018
Fluoride
413 µg/L 10%
of the EPA limit 4000 µg/L
worst single sample: 420 µg/L
3/3 SYR4 2012–2018
Nitrate
160 µg/L 1.6%
of the EPA limit 10000 µg/L
2/10 SYR4 2013–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
1/1 SYR4 2015
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) PhthalateDinosebDiquatEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Frequently asked questions about Heidel Rd Apts 139

Is Heidel Rd Apts 139 tap water safe to drink?

EPA monitoring detected 8 contaminants in Heidel Rd Apts 139's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Heidel Rd Apts 139's water?

EPA monitoring detected Copper, Lead, Lead, Arsenic, Barium, and others. The full list with the level and data source for each is above.

How many people does Heidel Rd Apts 139 serve?

Heidel Rd Apts 139 reports serving 40 people in Wisconsin, per its EPA record.

Has Heidel Rd Apts 139 had any water quality violations?

The EPA has 127 violations on file for Heidel Rd Apts 139, of which 8 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.