← Washington

Tap water quality report

Spo Co Water Dist 3 Sys 1

EPA monitoring tested this supplier for 109 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
16
detected
19,035
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Spokane

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
124
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2017-01-01 → 2017-12-31
MR Monitoring Resolved 2015-04-01 → 2015-06-30
MR Monitoring Resolved 2015-04-01 → 2015-06-30
MR Monitoring Resolved 2015-01-01 → 2015-03-31
MR Monitoring Resolved 2015-01-01 → 2015-03-31
MR Monitoring Resolved 2014-10-01 → 2014-12-31
MR Monitoring Resolved 2014-10-01 → 2014-12-31
MR Monitoring Resolved 2014-07-01 → 2014-09-30
MR Monitoring Resolved 2014-07-01 → 2014-09-30
MR Monitoring Resolved 2007-10-01 → 2007-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
6830 µg/L 68%
of the EPA limit 10000 µg/L
58/58 SYR4 2012–2019
TTHM
11.83 µg/L 15%
of the EPA limit 80 µg/L
39/39 SYR4 2012–2019
Dibromochloromethane
3.69 µg/L
No EPA limit set
38/45 SYR4 2012–2019
Bromoform
2.2 µg/L
No EPA limit set
35/44 SYR4 2012–2019
Bromodichloromethane
2.87 µg/L
No EPA limit set
33/43 SYR4 2012–2019
Chloroform
5.1 µg/L
No EPA limit set
19/46 SYR4 2012–2019
Lead
0.0016 mg/L 11%
of the EPA limit 0.0150 mg/L
10/10 LCR 2023
Total Haloacetic Acids (HAA5)
9.8 µg/L 16%
of the EPA limit 60 µg/L
8/37 SYR4 2012–2018
Dichloroacetic Acid
7.32 µg/L
No EPA limit set
6/39 SYR4 2012–2019
Arsenic
7.5 µg/L 75%
of the EPA limit 10 µg/L
4/4 SYR4 2017–2019
Dibromoacetic Acid
1.37 µg/L
No EPA limit set
4/38 SYR4 2012–2019
Nitrate-Nitrite
3110 µg/L 31%
of the EPA limit 10000 µg/L
3/3 SYR4 2017–2019
Fluoride
310 µg/L 7.8%
of the EPA limit 4000 µg/L
2/3 SYR4 2017–2019
Lithium
12 µg/L
No EPA limit set
2/10 UCMR-5 2023
Barium
130 µg/L 6.5%
of the EPA limit 2000 µg/L
1/3 SYR4 2017–2019
Trichloroacetic Acid
1.32 µg/L
No EPA limit set
1/39 SYR4 2012–2019
93 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
Kelly Williquette

Frequently asked questions about Spo Co Water Dist 3 Sys 1

Is Spo Co Water Dist 3 Sys 1 tap water safe to drink?

EPA monitoring detected 16 contaminants in Spo Co Water Dist 3 Sys 1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Spo Co Water Dist 3 Sys 1's water?

EPA monitoring detected Nitrate, TTHM, Dibromochloromethane, Bromoform, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Spo Co Water Dist 3 Sys 1 serve?

Spo Co Water Dist 3 Sys 1 reports serving 19,035 people in Washington, per its EPA record.

Has Spo Co Water Dist 3 Sys 1 had any water quality violations?

The EPA has 124 violations on file for Spo Co Water Dist 3 Sys 1, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.