← Washington

Tap water quality report

Sunset Water Distribution Assoc

EPA monitoring tested this supplier for 51 contaminants and detected 5. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

51
contaminants tested
5
detected
159
people served
2
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Island

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
52
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2011-10-01 → 2011-12-31
MCL Health-based Resolved 2010-01-01 → 2010-03-31
Other Monitoring Resolved 2025-07-01
MR Monitoring Resolved 2023-07-01 → 2023-09-30
MR Monitoring Resolved 2020-01-01 → 2020-03-31
MR Monitoring Resolved 2018-07-01 → 2018-09-30
MR Monitoring Resolved 2017-10-01 → 2017-12-31
Other Monitoring Resolved 2016-07-01
MR Monitoring Resolved 2012-01-01 → 2012-03-31
MR Monitoring Resolved 2011-04-01 → 2011-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
10/10 LCR 2024
Arsenic
12 µg/L 120%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
1/1 SYR4 2012
Barium
25 µg/L 1.3%
of the EPA limit 2000 µg/L
1/1 SYR4 2012
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/1 SYR4 2012
Fluoride
170 µg/L 4.3%
of the EPA limit 4000 µg/L
1/1 SYR4 2012
46 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalBenzeneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCopperCyanideCadmiumCarbon TetrachlorideChloroformDichloromethaneDalaponDibromochloromethaneDinosebEthylene DibromideEthylbenzeneGross Beta Particle ActivityLeadMercuryNitrateNitrate-NitriteNitritePentachlorophenolPicloramSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
Brett Angelocci

Frequently asked questions about Sunset Water Distribution Assoc

Is Sunset Water Distribution Assoc tap water safe to drink?

EPA monitoring detected 5 contaminants in Sunset Water Distribution Assoc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sunset Water Distribution Assoc's water?

EPA monitoring detected Lead, Arsenic, Barium, Chromium, Fluoride. The full list with the level and data source for each is above.

How many people does Sunset Water Distribution Assoc serve?

Sunset Water Distribution Assoc reports serving 159 people in Washington, per its EPA record.

Has Sunset Water Distribution Assoc had any water quality violations?

The EPA has 52 violations on file for Sunset Water Distribution Assoc, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.