← Washington

Tap water quality report

Lagoon Point Water District

EPA monitoring tested this supplier for 75 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

75
contaminants tested
12
detected
495
people served
1
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Island

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
90
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1994-08-01 → 1994-08-31
Other Monitoring Resolved 2025-07-01
MR Monitoring Archived 2025-01-01 → 2025-12-31
MR Monitoring Resolved 2022-04-01 → 2022-06-30
MR Monitoring Resolved 2022-01-01 → 2022-03-31
MR Monitoring Resolved 2021-07-01 → 2021-09-30
Other Monitoring Resolved 2014-07-01
MR Monitoring Resolved 2010-01-01 → 2010-12-31
MR Monitoring Resolved 2009-01-01 → 2009-12-31
MR Monitoring Resolved 2008-01-01 → 2010-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
4700 µg/L 47%
of the EPA limit 10000 µg/L
18/28 SYR4 2012–2019
Lead
0.0013 mg/L 8.7%
of the EPA limit 0.0150 mg/L
10/10 LCR 2023
Arsenic
5.35 µg/L 53%
of the EPA limit 10 µg/L
worst single sample: 5.5 µg/L
3/4 SYR4 2012–2019
Barium
28.4 µg/L 1.4%
of the EPA limit 2000 µg/L
worst single sample: 29 µg/L
2/4 SYR4 2012–2019
Nitrate-Nitrite
3238.5 µg/L 32%
of the EPA limit 10000 µg/L
worst single sample: 3400 µg/L
2/4 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
2.165 µg/L 3.6%
of the EPA limit 60 µg/L
worst single sample: 2.2 µg/L
2/5 SYR4 2012–2017
Chloroform
0.7000 µg/L
No EPA limit set
1/11 SYR4 2012–2018
Chromium
7 µg/L 7%
of the EPA limit 100 µg/L
1/4 SYR4 2012–2019
Dibromoacetic Acid
1.5 µg/L
No EPA limit set
1/5 SYR4 2012–2017
Gross Beta Particle Activity
92 pCi/L
No EPA limit set
1/1 SYR4 2017
TTHM
0.7000 µg/L 0.9%
of the EPA limit 80 µg/L
1/1 SYR4 2014
Trichloroacetic Acid
2.2 µg/L
No EPA limit set
1/5 SYR4 2012–2017
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCopperCyanideCadmiumCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitritePentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
Andrew Campbell

Frequently asked questions about Lagoon Point Water District

Is Lagoon Point Water District tap water safe to drink?

EPA monitoring detected 12 contaminants in Lagoon Point Water District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lagoon Point Water District's water?

EPA monitoring detected Nitrate, Lead, Arsenic, Barium, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Lagoon Point Water District serve?

Lagoon Point Water District reports serving 495 people in Washington, per its EPA record.

Has Lagoon Point Water District had any water quality violations?

The EPA has 90 violations on file for Lagoon Point Water District, of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.