Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2014-07-01 → 2014-09-30 |
| MCL | Health-based | Resolved | 2014-04-01 → 2014-06-30 |
| MCL | Health-based | Archived | 1999-10-01 → 1999-10-31 |
| MCL | Health-based | Archived | 1999-10-01 → 1999-10-31 |
| MCL | Health-based | Archived | 1999-10-01 → 1999-10-31 |
| MR | Monitoring | Unaddressed | 2025-07-01 |
| MR | Monitoring | Resolved | 2022-10-01 → 2022-12-31 |
| MR | Monitoring | Resolved | 2020-01-01 → 2020-03-31 |
| MR | Monitoring | Resolved | 2017-01-01 → 2019-12-31 |
| MR | Monitoring | Resolved | 2017-01-01 → 2019-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 263 µg/L 2.6% of the EPA limit 10000 µg/L | 12/34 | SYR4 | 2012–2019 |
| Lead | 0.00070 mg/L 4.7% of the EPA limit 0.0150 mg/L | 9/9 | LCR | 2025 |
| Barium | 48.075 µg/L 2.4% of the EPA limit 2000 µg/L
worst single sample: 52.2 µg/L | 4/4 | SYR4 | 2012–2019 |
| Antimony, Total | 2.65 µg/L 44% of the EPA limit 6 µg/L
worst single sample: 2.8 µg/L | 3/4 | SYR4 | 2012–2019 |
| Copper | 25.861 µg/L 2% of the EPA limit 1300 µg/L
worst single sample: 27.7 µg/L | 3/4 | SYR4 | 2012–2019 |
| Chloroform | 0.6730 µg/L No EPA limit set
worst single sample: 0.6900 µg/L | 2/8 | SYR4 | 2012–2018 |
| Fluoride | 284.1 µg/L 7.1% of the EPA limit 4000 µg/L
worst single sample: 291 µg/L | 2/4 | SYR4 | 2012–2019 |
| TTHM | 1.224 µg/L 1.5% of the EPA limit 80 µg/L
worst single sample: 1.27 µg/L | 2/2 | SYR4 | 2013–2017 |
| Arsenic | 20.1 µg/L 201% of the EPA limit, at the 95th percentile of samples — 10 µg/L | 1/4 | SYR4 | 2012–2019 |
| Bromodichloromethane | 0.5800 µg/L No EPA limit set | 1/8 | SYR4 | 2012–2018 |
| Cadmium | 1.28 µg/L 26% of the EPA limit 5 µg/L | 1/4 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 0.4000 pCi/L 8% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2012 |
| Combined Uranium | 8 µg/L 27% of the EPA limit 30 µg/L | 1/1 | SYR4 | 2012 |
| Lead | 10.2 µg/L 68% of the EPA limit 15 µg/L | 1/4 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 263 µg/L 2.6% of the EPA limit 10000 µg/L | 1/4 | SYR4 | 2012–2019 |
44 contaminants tested, none detected
Utility contact
Frequently asked questions about Stevens Co Pud - Mission Ridge
Is Stevens Co Pud - Mission Ridge tap water safe to drink?
EPA monitoring detected 15 contaminants in Stevens Co Pud - Mission Ridge's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Stevens Co Pud - Mission Ridge's water?
EPA monitoring detected Nitrate, Lead, Barium, Antimony, Total, Copper, and others. The full list with the level and data source for each is above.
How many people does Stevens Co Pud - Mission Ridge serve?
Stevens Co Pud - Mission Ridge reports serving 120 people in Washington, per its EPA record.
Has Stevens Co Pud - Mission Ridge had any water quality violations?
The EPA has 477 violations on file for Stevens Co Pud - Mission Ridge, of which 5 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.